Wi Lan Inc EB02 Benutzerhandbuch

Seite von 190
Bench Test Units
APR 2001 Rev 03
25
Performing Simple Network Tests
To test units within a simple network you require two AWE 120-58 units, a LAN connection, a PC and a 
crossover ethernet cable or hub connection. A ferrite block is placed around the 10/100BaseT Ethernet cable 
to prevent electromagnetic interference (EMI) from transferring from a unit to the Ethernet cable, and from 
the Ethernet cable to the unit. The ferrite block is included with the contents of the shipping box. Install a 
ferrite block when testing units, and ensure that a ferrite block is in place when units are installed in the field.
➧ 
To install the ferrite block
1.
Remove the ferrite block from the plastic packaging.
2.
Pull the clip and open the ferrite block. See 
3.
Place the Ethernet cable in the center of the open ferrite block. Locate the block approximately 4 cm 
from the cable connector end that plugs into the unit’s Ethernet port. See 
4.
Close the ferrite block around the Ethernet cable, making sure that the block snaps together. See 
1
Clip
1
Ferrite Block
2
3
2
4
4 cm
3