Wi Lan Inc EB03 Benutzerhandbuch

Seite von 190
Configuration
52
 AWE 120-24 Installation & Configuration Guide
Performing Link Monitor Test (Normal Mode)
The link monitor test can be run from either a base station or a remote unit that is set to Normal Mode. The 
test operates in parallel with the message stream, so it consumes some of the link’s total data capacity. You 
can control the ratio of test data to message data (and thereby control the amount of test data overhead) by 
setting the link monitor period. See 
 
for more information.
Note: Link monitor test stays in effect even if you power cycle or reboot units, so you must turn it off using 
the Link Monitor Period (0 = OFF) setting.
➧ 
To perform Link Monitor test from a base station
1.
Connect the test PC to the Serial port of the base station. See 
2.
Log in to the unit and go to the Main Menu.
3.
Select RF Station Configuration and press 
Enter
. The RF Station Configuration menu is 
displayed.
4.
Select Operating Mode and press 
Enter
. The data field highlights.
5.
Press the arrow keys to select Normal mode and press 
Enter
.
6.
Select RF Transmit Status and press 
Enter
. The data field highlights.
7.
Press the arrow keys to select unblocked and press 
Enter
.
8.
Select Link Monitor Remote Station Rank and press 
Enter
The data field highlights.
9.
Type the rank of the remote unit that you want to link to and press 
Enter
. (The rank is the identification 
number of the remote unit. The rank of a remote can be any number from 1 – 1000.  See 
10. Select Link Monitor/Output Power and press 
Enter
. Set it to Normal.
                     RF Station Configuration
    Operating Mode                        -> Normal Mode
    RF Transmit Status                       unblocked
    Link Monitor Period (0=OFF, 1-10000)     0
    Test Mode Timer Minutes (1-1000)         5
    Base Station Only Parameters
    Maximum Remote Distance                  5 Km
    Link Monitor Remote Station Rank         1
    Remote Station Only Parameters
    Throttle Enable                          off
    Throttle Level (1-100)                   10   (640 kps)
    Link Monitor/Output Power                Normal
    User Output Power Adjust Ceiling         -5  dB
    Signal Margin (6-31) dB                   6
    Current Output Power Level Adjust        -21