Wi Lan Inc EB03 Benutzerhandbuch

Seite von 190
Configuration
78
 AWE 120-24 Installation & Configuration Guide
Adjusting the Tx Power Level
Tx Power Level Adjust enables you to reduce the transmit power output level by up to 31 dB. For example, 
selecting a value of 0 sets the transmit power to maximum power, while selecting a value of –31 sets the 
transmit power to 31 dB below maximum power.  The value is the intial Tx power level and is reset 
automatically when automatic power level adjustment is performed. See 
➧ 
To adjust the Tx power output level
1.
From the Main Menu, select Radio Module Configuration and press 
Enter
. The Radio Module 
Configuration menu is displayed.
2.
Select Tx Power Level Adjust and press 
Enter
. The data field highlights.
3.
Scroll through the list and press 
Enter
 to select a power attenuation level. Choose a value between 0 
and –31, where 0 means no Tx power attenuation and –31 means Tx power is attenuated by 31 dB.
4.
Press 
Enter
. The new setting is displayed in the "New" column.
5.
Select Reboot New RF Configuration and press 
Enter
. The unit reboots and the AWE  120-58 
Login menu is displayed. The unit now runs using the "Current" acquisition code for the amount of time 
specified by the Current Test Minutes.
6.
To save the current setting(s) to flash memory, log in, go to the Main Menu, and select Radio Module 
Configuration,
 Save Current Config to Flash. See 
. 
7.
Press 
Esc
 to exit to the Main Menu.
                             Radio Module Configuration
                                      New         Current        Flash
Station Type                      Remote Unit   Remote Unit   Remote Unit
Station Rank (1-1000)             1             1             1
Center Frequency                  2.4400 GHz    2.4400 GHz    2.4400 GHz
Security Password 1  (Hex)        1             1             1
Security Password 2  (Hex)        10            10            10
Security Password 3  (Hex)        100           100           100
Security Password 4  (Hex)        1000          1000          1000
Security Password 5  (Hex)        10000         10000         10000
Scrambling Code      (Hex)        0             0             0
Acquisition Code     (0-15)       0             0             0
Config Test Minutes  (1-120)      30            30            30
Tx Power Level Adjust          -> 0 dB          0 dB          0 dB
Base Station Only Parameters
Repeater Mode                     off           off           off
System Symmetry Type              Asymmetric    Asymmetric    Asymmetric
Dynamic Polling Level (1-100)     1             1             1
Remote Station Only Parameters
Remote Unit RF Group (0-63)       0             0             0
Reboot New RF configuration       Press Enter to Execute
Save Current Config to Flash      Press Enter to Execute