Itron Inc. 100G Benutzerhandbuch

Seite von 27
Chapter 5  American/Actaris Commercial Meter Installation 
 
•  New tamper seals 
•  Four screws for securing the 100G ERT Module assembly to the meter. These screws 
have holes drilled into the heads to accept wire tamper seals. 
•  Four internal tooth star washers used to attach the meter to the index mounting plate. 
 
Materials Supplied By You 
You must supply the following items to install, initialize, and check the 100G ERT Module 
on the meter. 
•  Small and medium flat-blade or Phillips screwdrivers   Used to remove and tighten 
index and index-cover screws. 
•  Side-cutting plier/wire snips   Used for cutting wire seals, if necessary. 
•  Small putty knife   Used to remove all traces of old gaskets from the meter.  
•  Meter seals, wire seals, and seal press   Used to secure the meter from tampering, if 
necessary. 
•  11/32-inch nut driver or other blunt tool   Used to securely seat new tamper plugs 
over screw holes.  
•  FC200SR with EndPoint-Link or EndPoint-Link Pro software   Used to program  
and check ERT assembly. 
 
Replacement Screws 
Replacement screws for mounting the index cover must be slotted, zinc-plated, steel 
machine screws. Sizing options are shown below. 
For mounting 100G ERT Module assemblies on meters: 
•  Use 12 - 24 x 1/2-inch slotted, Fillister head machine screws, drilled to accept wire 
seals. 
 
Preinstallation Preparations 
Before installing the 100G ERT Module on a meter, verify that:   
•  All Itron gas modules are 100G ERT Modules for your brand of gas meters.  
•  The model numbers of all meters on which the 100G ERT Modules will be installed 
are included in the Meter Compatibility List. 
 
56 
Natural Gas Solutions 100G Installation Guide