Itron Inc. 100GDLA Benutzerhandbuch

Seite von 20
Installing the 100G ERT Module
Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters
71
A gap at the screw locations is normal both before and after the index cover 
mounting-plate screws are tightened.
7. Install the four ERT module mounting screws and tighten them, in a diagonal 
sequence. Turn each screw 1/4 to 1/2 turn after it contacts the mounting plate. If you 
are using a torque wrench, tighten to 72 inch-pounds. 
8. Place new tamper seals over screws and press the seals into place with an 11/32 inch 
nut driver, or other blunt tool. 
To attach the index and cover
1. Locate the gasket previously removed and place it on the index cover mounting plate.
2. Align the gasket screw holes with the mounting plate's screw holes.