Note: The password for every CGR is different. The password does not appear on the
screen as you enter it.
3. Type show module.
4. Confirm that the Itron CAM module location is shown (for example, CGR1000 Third
Party Module). In the example above, Mod 4 is Slot #4. Under Status, ok indicates
that the device is powered and active.
Powering Down the CAM
Note: In the example described here, the CAM is located in Slot #4. If your CAM is located
in Slot #5, the same procedure applies. In this case, use Slot #5.
1. Type conf t (configuration terminal). The prompt changes to (config).
2. Type hw power 4 (in this example, the CAM is located in Slot #4).
3. Type do show module.
4. If successful, the Status indicates powered-dn (powered down).
Note:
• If it is not showing powered down, verify that (config) shows in the prompt. If not,
re-enter conf t.
• Once (config) is shown in the prompt, issue the hw power 4 command a second
time.
• Verify that the Status is powered-dn with another do show module command.
Verifying the CAM Location
After the CAM is powered down, use the following procedure to check the hardware
components.
Note: In the example described here, the CAM is located in Slot #4. If your CAM is located
in Slot #5, the same procedure applies. In this case, use Slot #5.