Figure 2: Avoid installing near rotating machines
•
Select a location likely to intercept an intruder
moving across the coverage pattern (see Figure 3).
moving across the coverage pattern (see Figure 3).
Figure 3: Coverage Pattern
Avoid mounting the detector in locations
(such as above a doorway) where people
can pass in close proximity (0.5 m / 1.5 ft.)
of the detector.
(such as above a doorway) where people
can pass in close proximity (0.5 m / 1.5 ft.)
of the detector.
•
The surface should be solid and vibration-free.
•
Mounting height range is 1.8 m to 2.4 m (6 ft. to
8 ft.). The recommended height is 2.3 m (7.5 ft.).
Mounting height for Pet Applications is 2 m
(6.5 ft.).
8 ft.). The recommended height is 2.3 m (7.5 ft.).
Mounting height for Pet Applications is 2 m
(6.5 ft.).