VTech Telecommunications Ltd 80-9896-01 Benutzerhandbuch

Seite von 2
Adjust the sound sensitivity of the 
baby unit
You can choose to hear sounds from the baby 
unit all the time, or to hear sounds that exceed 
a certain level. You can use the parent unit to 
adjust the microphone sensitivity of your baby 
unit. The higher the sensitivity level, the more 
sensitive the baby unit is in detecting sounds 
for transmitting to the parent unit. The sound 
sensitivity is preset to 
Level 5
Sound sensitivity table for reference
Display
Sensitivity Description
 
High sensitivity level
The parent unit speaker is 
constantly on, and you will 
hear all sounds (including 
background noises) from 
your baby’s room.
 
 
Medium high 
sensitivity level
The parent unit speaker 
turns on for soft babbling 
and louder sounds from 
your baby. It remains 
quiet when your baby 
sleeps soundly.
 
  
Medium sensitivity level
The parent unit speaker 
turns on for loud babbling 
and louder sounds from 
your baby. It remains quiet 
when your baby makes 
soft sounds.
   
  
Medium low sensitivity 
level
The parent unit speaker 
turns on for crying and 
louder sounds from your 
baby. It remains quiet 
when your baby makes 
soft sounds.
       
Low sensitivity level
The parent unit speaker 
turns on for loud crying or 
screeching sounds from 
your baby. It remains quiet 
when your baby makes 
soft sounds.
Press 
menu when the parent unit is not  
in use.
Press 
select.
Press 
volume + or volume - to choose the 
sensitivity level.
Press 
select to confirm your selection.
1.
2.
3.
4.
BC
Baby unit overview
1
Projector
When it is on, it projects some image 
patterns to the user environment.
2
Microphone 
3
Control key panel
power on
Press to power on.
Press and hold to power off.
page
Press to start or stop paging parent unit.
volume +
Press to increase the listening 
volume or lullaby volume.
volume -
Press to decrease the listening 
volume or lullaby volume.
Press to turn on or off the projector 
and lullaby.

4
Magnetic base
5
Speaker
6
Temperature sensor
7
Power jack
Parent unit overview
1
sensor alerts
Press to turn on or off the sensor alert 
system.
2
Microphone
3
Visual sound indicator 
The visual sound indicator has two 
functions. One is to show the sound level 
detected by the baby unit. The other 
one is to show the volume level during 
speaker volume setting.
Sound level detected by the baby unit
   One to three green 
lights indicate a moderate sound level 
detected by the baby unit.
   Additional red 
lights indicate a higher sound level 
detected by the baby unit (e.g. baby 
crying loudly).
Speaker volume level
   One to three green 
lights indicate 
Level 1 to Level 3 of the 
speaker volume setting.
   Additional red 
lights indicate 
Level 4 to Level 5 of 
the speaker volume setting.
4
LCD panel
5
menu
Press to enter the settings menu 
while idle.
Baby Monitor Overview
6
Control key panel
select 
While in a menu, press to choose an 
item, or save a setting.
back
While in a menu, press to return to 
the previous screen.
volume +
Press to increase the speaker volume.
While in a menu, press to scroll up.
volume -
Press to decrease the speaker 
volume.
While in a menu, press to scroll down.

7
 
Battery level indicator
Light on when the parent unit is 
connected to AC power.
Light flashes when the parent unit 
battery is low and needs charging.
Light off when the parent unit battery is 
fully charged, or when not connect to  
AC power and with no battery installed .
8
(On/off)
Press to power on.
Press and hold to power off.

9
talk
Press and hold to talk to the baby 
unit; release to stop talking. 
While in a menu, press to return to 
idle screen.
10
Power jack
11
Speaker
12
Belt clip
13
Battery compartment cover
What’s in the box
Power on or off the baby unit
Press
 
power on to turn on the baby unit. The 
power on lights up
.
Press and hold 
power on again to power off 
the baby unit. The 
power on
 turns off.
Power on or off the parent unit
Press   to power on the parent unit. The 
screen turns on.
Press and hold   again to power off the 
parent unit. The screen turns off.
NOTE
The parent unit powers on automatically once 
it is connected to AC power or battery installed. 
The baby unit also powers on automatically once 
connected to AC power. 
Adjust the speaker volume for baby unit
Press 
volume + or volume - on the baby 
unit at any time.
Adjust the speaker volume for parent unit
You can adjust the speaker volume from 
VOLUME 1 to
to 
VOLUME 5, or turn it off. The 
speaker volume is preset to 
VOLUME 3.
Press 
volume + or volume - when the 
parent unit is not in use.
When the speaker volume is set to off, the 
screen displays   .
Using the baby monitor
Press 
volume + or volume - to choose On 
or 
Off.
Press 
select to confirm your selection. The 
screen displays 
Saved and you hear a 
confirmation tone.
NOTES
Each time you set the vibration alert to 
ON, the 
parent unit vibrates briefly after you press 
select
.
We recommend you not to turn on the vibration 
alert and the lullaby at the same time, as the 
lullaby will trigger the vibration alert frequently.
The vibration alert setting on each parent unit is 
independent.
Projector
You can turn on or off the baby unit projector.
Press 
menu when the parent unit is not in use.
Press 
volume + or volume - to choose 
Project, then press select.
Press 
volume + or volume - to choose On 
or 
Off.
Press 
select to confirm your selection. The 
screen displays 
Saved and you hear a 
confirmation tone. 
LCD language
You can select a language (English, French or 
Spanish) to be used in all screen displays. The 
language is preset to 
English.
Press 
menu when the parent unit is not in use.
Press 
volume + or volume - to choose 
Language, then press select.
Press 
volume + or volume - to choose 
EnglishFrançais or Español.
Press 
select to confirm your selection. The 
screen displays 
Saved and you hear a 
confirmation tone. 
NOTE
The language setting on each parent unit is 
independent.
Temperature
You can change the settings for the 
temperature’s range, alerts, format.
Set the temperature range
You can set the desired minimum and maximum 
room temperature of the baby unit.
Press 
menu when the parent unit is not in use.
Press 
volume + or volume - to choose 
Temperature, then press select.
Press 
select to select Range.
Press 
volume + or volume - to adjust the 
minimum temperature between 
55 F and  
59 F (11 C and 20 C), then press select.
3.
4.
1.
2.
3.
4.
1.
2.
3.
4.
1.
2.
3.
4.
NOTE
To enter the sensitivity menu of the parent unit, 
the baby unit must be turned on.
Set date and time
You can set the date and time to be displayed 
on the idle parent unit.
Press 
menu when the parent unit is not in use.
Press 
volume + or volume - to choose Set 
date/time, then press select.
Press 
volume + or volume - to choose the 
month, then press 
select.
Press 
volume + or volume - to choose the 
day, then press 
select.
Press 
volume + or volume - to choose the 
year, then press 
select.
Press 
volume + or volume - to choose the 
hour, then press 
select.
Press 
volume + or volume - to choose the 
minute, then press 
select.
Press 
select to confirm your selection. You 
hear a confirmation tone.
Sound alert
Sound alert feature works only when the parent 
unit is in mute.
If you turn on the sound alert, the parent unit beeps 
when the baby unit detects sounds which light up 
four sound level indicators on the parent unit.
When the sound alert of the parent unit is turned 
on,   displays. The sound alert is preset to 
Off.
Press 
menu when the parent unit is not in use.
Press 
volume + or volume - to choose 
Sound alert, then press select.
Press 
volume + or volume - to choose On 
or 
Off.
Press 
select to confirm your selection. The 
screen displays 
Saved and you hear a 
confirmation tone.
NOTE
The sound alert setting on each parent unit is 
independent.
Vibration alert
You can turn on the vibration alert so that the 
parent unit vibrates when the baby unit detects 
sounds which light up four sound level indicators 
on the parent unit.
When the vibration alert of the parent unit is 
turned on,   displays. The vibration alert is 
preset to 
Off.
Press 
menu when the parent unit is not in use.
Press 
volume + or volume - to choose 
Vibration alert then press select.
1.
2.
3.
4.
5.
6.
7.
8.
1.
2.
3.
4.
1.
2.
Congratulations
on purchasing your new VTech product. Before 
using this product, please read  
Important safety instructions
For support, shopping, and everything new at 
VTech, visit our website at  
www.vtechphones.com.
Register online to get an additional  
3-month warranty!
Visit www.vtechphones.com.
m
k
l
j      
h
i
c
d
b
a
c
e
g
f
Sensor unit
Magnet unit
Spacer for 
sensor unit
Spacers for 
magnet unit
Double-sided 
mounting tapes
Screws x 2
Small screw x 2
Press 
volume + or volume - to adjust the 
maximum temperature between 
83 F and  
86 F (21 C and 30 C), then press select.
Press 
select to confirm your selection. The 
screen displays 
Saved and you hear a 
confirmation tone. 
Turn on or off the temperature alerts
You can turn on or off the alerts which reminds 
you the current room temperature is beyond of 
temperature range.
Press 
menu when the parent unit is not in use.
Press 
volume + or volume - to choose 
Temperature, then press select.
Press 
volume + or volume - to choose 
Alerts, then press select.
Press 
volume + or volume - to choose On 
or 
Off.
Press 
select to confirm your selection. The 
screen displays 
Saved and you hear a 
confirmation tone. 
Set the temperature format
You can set the temperature format to 
Celsius 
or 
Fahrenheit.
Press 
menu when the parent unit is not in use.
Press 
volume + or volume - to choose 
Temperature, then press select.
Press 
volume + or volume - to choose 
Format, then press select.
Press 
volume + or volume - to choose 
Celsius or Fahrenheit.
Press 
select to confirm your selection. The 
screen displays 
Saved and you hear a 
confirmation tone. 
Sensor settings
You can change the settings for each individual 
sensor paired to the baby unit.
Press 
menu when the parent unit is not in use.
Press 
volume + or volume - to choose 
Sensor settings, then press select to enter 
the sensor settings menu.
Turn the sensor alert on or off
You can turn on or off the sensor alert for each 
individual sensor.
Press 
menu when the parent unit is not in use.
Press 
volume + or volume - to choose 
Sensor settings, then press select to enter 
the sensor settings menu.
Press 
select to select Set alert.
Press 
volume + or volume - to choose 
the desired sensor, then press 
select.
4.  Press 
volume + or volume - to choose On 
or 
Off.
5.  Press 
select to confirm your selection. The 
screen displays 
Saved and you hear a 
confirmation tone. 
5.
6.
1.
2.
3.
4.
5.
1.
2.
3.
4.
5.
1.
2.
1.
2.
3.
Parent unit
Baby unit
Battery compartment 
cover
Baby unit adapter
Battery
Parent unit adapter
Parent unit display screen 
messages
BATTERY LOW 
AT PARENT 
UNIT 
The parent unit uses only 
the rechargeable battery 
pack and it needs to be 
recharged.
BATTERY LOW 
AT SENSOR X*
The sensor battery is low 
and it needs to be replaced.
SENSOR X* 
is open / 
MOTION X* 
detected 
motion
The monitored door, 
window, or medicine 
cabinet is opened, or there 
is a motion detected in the 
monitored area.
NO LINK TO 
BABY UNIT
When the link between the 
parent unit and the baby 
unit is lost continuously for 
over 10 seconds.
PAGING
All idle parent units are 
being paged by the baby 
unit.
Saved
Your selection has been 
saved.
SEARCHING...
The parent unit is out of 
range of the baby unit, 
or the baby unit is out of 
power.
TALKBACK
The parent unit is talking to 
the baby unit.
<X> new 
event(s)
The number of new sensor 
activity(ies).
68
o
F/20
o
C
The real-time temperature 
of the baby unit.
90
o
F/32
o
TOO HOT / 
TOO COLD
The temperature of the 
baby unit is too high or too 
low.
*
    
Sensor X or Motion X refer to the sensor’s name.  
      
X refers to the system-assigned number of the  
      sensor. You can edit the sensor’s name to your  
      preferred name. See 
Rename the sensor.
High 
sensitivity
Low 
sensitivity
Level 5
Level 4
Level 3
Level 2
Level 1
User’s manual
User’s manual
Sensor notification
You can choose the type of notification to 
receive when a sensor is triggered. The preset 
alert notification is 
Msg, tone, voice.
Definitions of notification types:
Msg - The LCD display messages of alert on 
the handset and telephone base.
Tone - The long alert tone that you will hear 
prior to the voice announcement and LCD 
display message. 
Voice - The voice announcement of the alert, at 
the handset and telephone base. 
Alerts 
type
Alert 
tone
Voice 
annc
LCD 
msg
Sensor 
log 
event
Msg, tone, 
voice
Msg & 
tone
--
Message 
only
--
--
Press 
menu when the parent unit is not in use.
Press 
volume + or volume - to choose 
Notifications, then press select.
Press 
volume + or volume - to choose  
All alerts offAll alerts onMsg & tone, or 
Message only
Press 
select to confirm the setting. The 
screen displays 
Saved and you hear a 
confirmation tone. 
Sensor log
The sensor log menu appears when there is at 
least one sensor paired to the baby unit.
The sensor log stores a maximum of 50 entries 
for sensor activities from all sensors.
Press 
menu when the parent unit is not in use.
Press 
volume + or volume - to choose 
Sensor log, then press select to view the 
sensor log entries. 
Rename the sensor
You can rename each individual sensor to a 
customized name.
Press 
menu when the parent unit is not in use.
Press 
volume + or volume - to choose 
Rename, then press select.
Press 
volume + or volume - to choose the 
sensor to rename, then press 
select
Press 
volume + or volume - to choose 
the desired sensor, then press 
select.
4.  Press 
volume + or volume - to choose a name.
5.  Press 
select to confirm the name. The 
screen displays 
Saved and you hear a 
confirmation tone. 
1.
2.
3.
4.
1.
2.
1.
2.
3.
sensor
alert
c
g
d
e
b
f
a
sensor
alert
alert
sensor
User’s manual
DM271 
DM271-102
Wireless Monitoring System  
with Safe & Sound
®  
Digital Audio Monitor
Go to  
www.vtechphones.com 
to register your product 
for enhanced warranty 
support and the latest 
VTech product news.
> 1 cm 
   (0.4 inch)
> 1 cm 
   (0.4 inch)
> 1 cm 
   (0.4 inch)
> 1 cm 
   (0.4 inch)
1 set for DM271-102
1 set for DM271/DM271-102
Installation 
guide
Installation guide
 
1 –  Magnet unit
2 –  Sensor unit
Sensor unit overview
1 –  Latch button
Press to open the battery compartment 
case.
2 –  Back cover
3 –  Pair button
When the sensor has been 
deregistered from the baby unit,  
press and hold to enter the registration 
mode.
4 –  LED light
Flashes red when the sensor is in the 
registration mode.
5 –  Battery compartment case
Open/closed sensor overview
Parent unit display icons
Connection status
 displays when strong signal 
strength is detected between the 
baby unit and the parent unit.
 displays when moderate signal 
strength is detected between the 
baby unit and the parent unit.
 displays when the weak link signal 
strength is detected between the 
baby unit and the parent unit.
 flashes when the link between the 
baby unit and the parent unit is lost.
Projector and lullaby
Displays when the lullaby and the 
projector of the baby unit is on. 
Projector only
Displays when the projector of the 
baby unit is on.
Sound alert
Displays when the sound alert of the 
parent unit is turned on.
Flashes when there are sounds 
detected from the baby unit.
Vibration alert
Displays when the vibration alert of 
the parent unit is turned on.
Flashes when there are loud sounds 
detected from the baby unit.
Mute
Displays when the volume is turned off.
Sensor
The door, window, or medicine cabinet 
is opened; or there is a motion 
detected in the monitored area.
Sensor alerts on
Sensor alert system is turned on
Battery status
 animates when 
the battery is charging.
 displays solid when the battery is 
fully charged.
 flashes when battery is in low 
level and needs charging.
No battery icon displays when there 
is no battery installed.
Parent unit display overview