Diaphragm Meter Installation 
 
13. Thoroughly apply acetone to the area where you will install the encoder. Do not touch the cleaned area of 
the index face before the encoder is installed.  
 
14. Slide the thin end of the encoder spacing tool down over the magnet hub. 
  
 
15. Peel the strip of protective plastic off the adhesive side of the module's encoder. 
 
Important  You must do the next two steps exactly as described or the 100G series remote gas module 
will not work properly. 
16. Press the curved side of the encoder firmly against the side of the encoder spacing tool as shown below, 
with the adhesive side down. 
 
17. Slide the encoder down along the side of the encoder spacing tool until it touches the surface of the index 
(as shown below). Using moderate pressure, hold the encoder firmly against the index, without moving, 
for 15 seconds to permanently apply the encoder. 
 
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount 
83  
 