Bird Technologies Group 61470A Benutzerhandbuch

Seite von 40
Bird Technologies                             Manual 7-9558-2.3                              05/14/15                                Page 12
may have to be narrowed and it’s input attenua-
tion reduced. The isolation value measured
should exceed the signal booster’s gain figure
by at least 15 dB.
5) Repeat step 4 again with the signal generator
set at the passband edges in order to see if the
isolation is remaining relatively constant over
the complete width of the passband.
6) Repeat the isolation measurements if neces-
sary at other system passbands to determine
the overall minimum isolation value for the sys-
tem. Physical modification of the antenna sys-
tem maybe required in order to reach an
acceptable minimum value.
RF EXPOSURE
To comply with FCC RF exposure compliance
requirements, a separation distance of at least 90
cm must  be m aintained be twee n the Donor
antenna of this device and all persons. To comply
with FCC RF exposure compliance requirements, a
separation distance of at least 22.2 cm must be
maintained between the DAS antenna of this
device and all persons. This device must not be co-
located or operating in conjunction with any other
antenna or transmitter.
EXPOSITION RF
Pour conformer aux exigences d'exposition de
FCC RF, une distance de séparation d'au moins 90
cm doit être maintenue entre les Donor antenne de
cet appareil et toutes les personnes. Pour con-
former aux exigences d'exposition de FCC RF, une
distance de séparation d'au moins 22.2 cm doit
être maintenue entre les DAS antenne de cet
appareil et toutes les personnes. Cet appareil ne
doit pas être co-localisé ou exploités en conjonc-
tion avec toute autre antenne ou transmetteur.
SIGNAL FLOW BLOCK DIAGRAM
Figure 4 is the signal flow block diagram of the
standard signal booster model 614. Figure 5
shows the front view of the booster cabinet. In the
Digital Booster design the channel modules are bi-
directional with each module containing one down-
link branch and one uplink branch. The branches
are functionally identical because the same circuit
board designs are used in each branch. The uplink
and downlink branches may be programmed to any
frequency in the appropriate band.
Figure 4: Signal flow block diagram of the signal booster.