Section 3: Installing the LE4000
When a signal is reveived back from the central station, The bottom signal strength LED turns on solid.
Red
Blue
Blue/Green (Top)
Blue/Green (Bottom)
ON
ON
ON
ON
If at least one of the central stations did not respond back to the communicator, the signal strength LED corresponding to that central
station will turn off. Once the initialization sequence is complete, the LE4000 will move on to steady state operation.
Step 6 - Mount the LE4000
Note: If using an LE4000 trim plate, snap the LE4000 back plate onto the trim plate before mounting to the wall. If flush mounting or
using with an extension antenna, remove the provided breakaway from the trim plate prior to mounting.
1. Using the mounting holes on the LE4000 backplate, mark the four screw locations. Drill the anchor screw holes. NOTE:
Check for cable conduits and water pipes before drilling.
2. Inspect the mounting surface. Ensure that the surface is flat and will hold the wall tamper closed when mounted. Using anchor
screws (not provided), mount the cabinet to the wall.
3. Run the cables through the cable entry [13] or through the cabinet cable run knockout [15].
4. Complete the connections on the terminal blocks [12].
5. Reattach the front cover [1] securely to the cabinet.
Note: Refer to the wiring diagram at the end of this manual.