Digital Security Controls Ltd. 17TL280LER Benutzerhandbuch
Trouble
indication
Trouble
Indicator
Digit
Possible
Causes
Trouble Possible Solution
LED – 2
Flashes
Flashes
Supervision
Trouble
Communicator Enabled).
l
Ensure the PC-LINK cable between the panel and
communicator is connected properly (not reversed) and
is securely in place.
communicator is connected properly (not reversed) and
is securely in place.
Yellow LED
– 5 Flashes
– 5 Flashes
05
Cellular
Trouble
l
Confirm that cellular service is available and active in the
area.
area.
l
Check all antenna connections.
l
Ensure average radio signal strength is CSQ 5 or
higher. (See Table 7 ).
higher. (See Table 7 ).
l
Ensure the SIM card is properly inserted into the SIM
card holder.
card holder.
l
Ensure the SIM card has been activated (could take up
to 24 hrs after install).
to 24 hrs after install).
l
If this trouble persists, relocate the panel (and
communicator) or install an external antenna extension
kit.
communicator) or install an external antenna extension
kit.
Yellow LED
– 6 Flashes
– 6 Flashes
06
Ethernet
Trouble
l
Check with the ISP to confirm Internet service is active in
the area.
the area.
l
Ensure the Ethernet cable is securely inserted into the
RJ45 jack of the communicator and the
hub/router/switch.
RJ45 jack of the communicator and the
hub/router/switch.
l
Check the link light on the hub/router/switch is ON. If link
light is OFF, start the hub/router/switch.
light is OFF, start the hub/router/switch.
l
If DHCP is used, ensure that the unit has an assigned IP
address from the server. In Section [851] [992] verify a
valid IP address is programmed. If not, contact the
network administrator.
address from the server. In Section [851] [992] verify a
valid IP address is programmed. If not, contact the
network administrator.
l
If problem persists, replace the Ethernet cable and
RJ45 connector.
RJ45 connector.
Yellow LED
– 7 Flashes
– 7 Flashes
07
Receiver Not
Available
l
Ensure that the Ethernet path has Internet connectivity.
l
If using a static IP address, confirm that the gateway
and subnet mask are entered correctly.
and subnet mask are entered correctly.
l
If the network has a firewall, ensure the network has the
programmed outgoing ports open (default UDP port
3060 and port 3065).
programmed outgoing ports open (default UDP port
3060 and port 3065).
l
Ensure that all the receivers are programmed for
DHCP or have the proper IP address and port number.
DHCP or have the proper IP address and port number.
l
Ensure the cellular receiver APNs have been
programmed with the access point name provided by
the cellular provider.
programmed with the access point name provided by
the cellular provider.
l
If Common Mode is used, and only one path is initialized
while the other path is not successful, generate a
manual test transmission over both paths or power
cycle the communicator to recover the ‘Receiver Not
Available’ trouble.
while the other path is not successful, generate a
manual test transmission over both paths or power
cycle the communicator to recover the ‘Receiver Not
Available’ trouble.
Yellow LED
– 8 Flashes
– 8 Flashes
08
Receiver
Supervision
Trouble
l
This trouble is indicated when supervision is enabled
and the unit is not able to successfully communicate with
the receiver.
and the unit is not able to successfully communicate with
the receiver.
l
If this trouble persists, contact the central station.
Yellow LED
- 9 Flashes
09
FTC Trouble
l
The unit has exhausted all communications attempts to
all programmed receivers for events generated by the
communicator.
all programmed receivers for events generated by the
communicator.
l
Restart the system, if trouble persists, contact the
dealer.
dealer.
Yellow LED
– 12
0C
Module
Configuration
l
This indication appears when section [021] system
account code or sections [101]; [111]; [201]; and [211]
receiver account code have not been programmed.
account code or sections [101]; [111]; [201]; and [211]
receiver account code have not been programmed.
17