ADCP-75-136 
• Issue 1 • November 2002 
Page 53 
©
 2002, ADC Telecommunications, Inc. 
  3.  Connect the DC power cable to the RJ-45 circuit access tool (see Figure 28).  
  4.  Using  a  DC  voltmeter,  verify  that  the  DC  voltage  level  is  between  34  and  48  Vdc 
between
 any set of positive and negative (+/-) terminals at the RJ-45 circuit access tool 
as
 shown in Figure 29. Due to source current limiting at the DHU or DEU, low voltage 
can
 mean excess wire resistance, low source voltage, or excess remote current.  
 
  WarningThe DRU uses 48 Vdc power. To avoid electric shock or burns, use extreme care 
when
 working near exposed terminals or uninsulated cables. Be careful not to touch exposed 
terminals
 or to cause a short between terminals when checking voltage levels.  
16206-B
POSITIVE (+)
TEST POINTS
1, 3, 5, AND 7 
NEGATIVE (-)
TEST POINTS
2, 4, 6, AND 8
 
Figure 29. RJ-45 Circuit Access Tool Pin/Wire Designations 
  5.  Disconnect RJ-45 circuit access tool from the DRU. 
  6.  Use the DC voltmeter to check for open pin connections by checking for voltage between 
the
 +/– pairs on the RJ-45 circuit access tool (see Figure 29). 
  7.  Disconnect the DC power cable from the RJ-45 circuit access tool. 
  8.  Re-connect DC power cable to the DRU. 
6.5  DHU or DEU Fan Replacement Procedure 
It
  is  recommended  that  the  fans  (catalog  #  DGVI-100000FAN)  be  replaced  every  five  years. 
Replacement
 of a fan requires that the DHU or DEU be turned off for a short period of time. This 
will
 drop all existing calls, cause a temporary loss of service, and generate a major alarm. Use the 
following
 procedure to replace the cooling fans within the DHU or the DEU:  
  1.  Before touching the DHU or DEU or handling a fan, slip on an Electro-Static Discharge 
(ESD)
 wrist strap and connect the ground wire to an earth ground source. Wear the ESD 
wrist
 strap while completing each section of the fan installation procedure.  
 
  WarningElectronic components can be damaged by static electrical discharge. To prevent 
ESD
 damage, always wear an ESD wrist strap when working on the DHU or DEU and when 
handling
 electronic components.  
  2.  Observe  the  fans  (located  on  right  side  of  enclosure)  to  determine  which  fan  requires 
replacement.
  The  faulty  fan  may  be  stopped,  running  at  a  reduced  speed,  or  the  fan 
bearing
 may be noisy.  
    Note: Because the Mean Time Between Failures (MBTF) is the same for both fans, it may be 
more
 efficient to replace both fans at the same time.  