ADC Telecommunications Inc. DLCSMR3D Benutzerhandbuch

Seite von 34
ADCP-75-179 • Preliminary Issue A • September 2004 • Section 3: Operation
Page 3-11
© 2004, ADC Telecommunications, Inc.
2. Click on the HOST Site Name  Edit  button (see 
Figure 3-6
). The Site Name pop-up
screen will open as shown in 
Figure 3-7
. Enter a unique name for the HOST. The name
may be up to 32 characters long and must not contain any spaces. The name may include
numbers, punctuation, and upper or lower case letters and must always begin with a letter.
Click on OK to close the screen and make the changes take effect. 
Figure 3-7. HOST Site Name Pop-Up Screen
3. Click on the HOST Site Number Edit button (see 
Figure 3-6
). The Site Number pop-up
screen will open. Enter any number (must be unique) between 1 and 24 and then click on
OK to close the screen and make the changes take effect. 
4. Check the REMOTE Site Number field (see 
Figure 3-6
). The REMOTE Site Number
does not have to be entered. When the HOST Site Number is entered, the system will
automatically enter the same number for the REMOTE Site Number. 
5. Click on the REMOTE Site Name Edit button (see 
Figure 3-6
). The Site Name pop-up
screen will open. Enter a unique name for the REMOTE. The name may be up to 32
characters long and must not contain any spaces. The name may include numbers,
punctuation, and upper or lower case letters and must always begin with a letter. Click on
OK to close the screen and make the changes take effect. 
6. Open the Tools menu at the top of the main window and then select Refresh Catalog to
make the new Host and Remote site names appear in the View menu. 
2.5
Enter Host Forward Attenuation
The HU internal forward path attenuator setting determines the maximum composite output
signal level at the STM antenna port. The appropriate attenuation value for any particular
system is based on the number of channels the system is transporting and the signal level of the
composite forward path signals input at the host units RF IN ports. By default, the forward path
attenuator is set to 31 dB. 
The maximum output power that can be provided by the system is 43.4 dBm (22 Watts). The
total forward path gain that is provided by the system (with host and remote forward attenuators
set to 0 dB) is 85 dBm. Use the following procedure to set the forward path attenuation to
provide the maximum composite output signal level: 
1. Click on the HOST RF tab. The HOST RF display will open within the EMS main
window as shown in 
Figure 3-8