ADCP-75-210 • Issue 1 • November 2006
Page 64
© 2006, ADC Telecommunications, Inc.
3. Slide the RDC module into the designated slot within the RAN chassis. 
4. Lock the IEL handles on the top and bottom of the RDC module into the chassis and
tighten the handle screws. 
5. Using an SMA coaxial cable (1955000P081), connect one end to the PRI IN port on the
RDC module and the other end to the appropriate P OUT port on the C/MCPLR or P/
MCPLR module. Each P OUT port is associated with a different band.
6. Using an SMA coaxial cable (1955000P081), connect one end to the DIV IN port on the
RDC module and the other end to the appropriate D OUT port on the C/MCPLR or P/
MCPLR module. Each D OUT port is associated with a different band. For more
information on these ports, refer to the sections identified in the note above.
                                                                                                                                                                                                 21235-AX
Figure 44. Installing an RDC Module
4.1.6
Installing a RAN Up Converter (RUC2.X or RUC3) Module
The RAN Up Converter (RUC2.X or RUC3) module may be installed into either of two slots in
the RAN chassis, depending on the band for which the module will be used. One  module is
required for each two bands. The two slots are:
• Slot 11 (labeled RUC A2): used for first and second bands
• Slot 14 (labeled RUC A5): used for third and fourth bands
Note: For more information on the C/MCPLR module ports, see 
Section 1.7.9, 800 MHz
Multicoupler (C/MCPLR), on page 20
. For more information on the P/MCPLR module
ports, see 
Section 1.7.10, 1900 MHz Multicoupler (P/MCPLR), on page 22