ADCP-75-114 • Issue C • June 2001 
Page 17 
©
 2001, ADC Telecommunications, Inc. 
3 OPERATION 
This
 section provides guidelines for turning-up the RIU, verifying that the RIU is operating 
properly,
  setting  the  forward  and  reverse  path  signal  levels,  and  correcting  any  installation 
problems.
  
3.1  Tools and Materials 
The
 following tools and materials are required in order to complete the procedures in this section:  
• 
Portable
 spectrum analyzer or network analyzer 
• 
Pencil
 or pen 
• 
Writing
 pad 
3.2  Turn-Up Unit and Verify Operation 
The
  process  of turning-up the RIU and verifying operation involves setting the forward and 
reverse
 path signal levels, turning on the power, verifying that the LED indicator shows normal 
operation,
 and then measuring the forward and reverse path signal levels. Refer to Table 3 for a 
detailed
 description of the ALARM LED indicator.  
Table 3. Remote Interface Unit LED Indicator 
INDICATOR 
COLOR 
DESCRIPTION 
ALARM
 
 
Green
 
Yellow
 
Red
 
Off
 
Indicates
 if the RIU is normal or if a fault is detected.  
RIU
 in normal state, no faults detected.  
High
 temperature fault detected. (Minor alarm) 
Over
 or undercurrent fault on power amplifier detected. (Major alarm) 
AC
 power off or RIU internal fault.  
Use
 the following procedure to power-up the system: 
  1.  Temporarily disconnect the alarm system or notify the alarm system provider that testing 
is
 in progress.  
  2.  Adjust the forward and reverse path signal levels as specified in sections 3.3 and 3.4.  
  3.  Verify that the donor antenna is properly installed and connected.  
 
  Note: To comply with Maximum Permissible Exposure (MPE) requirements, antennas must be 
installed
 to provide at least 20 centimeters (8 inches) of separation from all persons per FCC 
47
 CFR part 2.1091.  
  4.  Verify that the RIU is connected to the appropriate AC outlet.  
  5.  Place the ON/OFF switch on the RIU in the ON position (press I).  
  6.  Verify that the ALARM LED on the RIU turns green.  
  7.  Check the forward path RF signal level at the DHU RF IN port and verify that the DHU 
input
 signal level is –20 dBm. Re-adjust FWD LEVEL ADJ rotary switches to add or 
remove
 gain if required.