SEGA Interactive Co. Ltd. DKT06214 Benutzerhandbuch
6. Performance
6.1 Operational performance
No Item
Standard
6.1.1
Operational power supply
voltage
voltage
5±0.25V (ripple voltage 100mVpp or
less)
less)
6.1.2 Consumption
current
Maximum 500mA (carrier output
status)
status)
6.1.3
Antenna output frequency
(carrier wave)
(carrier wave)
13.56MHz ±20ppm. or less
6.1.4 Data
rate
26.48kbps
(Reader/Writer Module ⇔ RFID chip)
(Reader/Writer Module ⇔ RFID chip)
6.1.5
Host side communications
format
Communication speed
Synchronization
Start bit
Data count
Stop bit
Parity
format
Communication speed
Synchronization
Start bit
Data count
Stop bit
Parity
UART half duplex
18.75kbps
Asynchronous
1 bit
8 bit
1 bit
1 bit/even number
18.75kbps
Asynchronous
1 bit
8 bit
1 bit
1 bit/even number
6.1.6
Reception circuit parameter
setting
setting
Resister settings by command
・
Slice level setting 4 stage
・
Amp gain setting 16 stage
(For details, see the communications
IC data sheet.)
<Automatic adjustment of reception amp gain>
At the development evaluation stage, determine the gain setting for minimum
error in communications and set this gain as the default value. If there has been an
error in communications and communications still cannot be established even after
retrying, run software so that the value set for gain is raised or lowered
automatically.
It is recommended that the value be raised or lowered from the default value in
consideration of the operational environment (power supply voltage, ambient
temperature), disparities in communication distances, and disparities in
communication performance on the tag side.
(Example)
Default
“2A”
Æ
2C
Æ
28
Æ
2E
Æ
26
Æ
2B
Æ
29
Æ
2D
Æ
27
Æ
2F
Æ
return to default value)
(Multiple retries take place for each gain.)
4