SEGA Interactive Co. Ltd. DKT06214 Benutzerhandbuch

Seite von 6
6. Performance 
 6.1 Operational performance 
No Item 
Standard 
6.1.1 
Operational power supply 
voltage 
5±0.25V (ripple voltage 100mVpp or 
less) 
6.1.2 Consumption 
current 
Maximum 500mA (carrier output 
status) 
6.1.3 
Antenna output frequency 
(carrier wave)   
13.56MHz ±20ppm. or less 
6.1.4 Data 
rate 
26.48kbps 
(Reader/Writer Module ⇔ RFID chip) 
6.1.5 
Host side communications 
format 
   Communication speed 
   Synchronization 
      Start bit 
   Data count 
      Stop bit 
      Parity 
UART half duplex 
18.75kbps 
Asynchronous 
1 bit 
8 bit 
1 bit 
1 bit/even number 
6.1.6 
Reception circuit parameter 
setting 
Resister settings by command   
・  
Slice level setting        4 stage 
・  
Amp gain setting    16 stage 
(For details, see the communications 
IC data sheet.) 
 
 
 
<Automatic adjustment of reception amp gain>
 
At the development evaluation stage, determine the gain setting for minimum 
error in communications and set this gain as the default value. If there has been an 
error in communications and communications still cannot be established even after 
retrying, run software so that the value set for gain is raised or lowered 
automatically.
 
It is recommended that the value be raised or lowered from the default value in 
consideration of the operational environment (power supply voltage, ambient 
temperature), disparities in communication distances, and disparities in 
communication performance on the tag side.
 
   
(Example)
 
          Default 
“2A” 
Æ
 2C 
Æ
 28 
Æ
 2E 
Æ 
26 
Æ
 2B 
Æ
 29 
Æ
 2D 
Æ
 27 
Æ
 2F 
       
Æ
 
return to default value)
 
        (Multiple retries take place for each gain.)
 
 
4