Technicolor Connected Home USA LLC TCA203 Benutzerhandbuch

Seite von 84
Appendix E: Installer Quick Reference (SIA)
173
Feature
Description
Ranges & Defaults
mode and Arm Stay mode. Exit Delay period works
the same way as non-remote arming.
figurable.
Abort Window
Length of time after an alarm sounds for the cus-
tomer to enter a valid keypad code to prevent
alarm from being sent to the central monitoring
station.
Default: 30 seconds
Range: Minimum is 15 sec-
onds and the maximum is 45
seconds
Disarming During
the Abort Window
System is disarmed by entering a valid keypad
code on the TouchScreen or a key pad. If an
invalid keypad code is entered, the alarm restarts.
This feature is not con-
figurable.
Aborting
If system is disarmed with within the Abort Win-
dow, no alarm transmission occurs. Contacts can
opt not to receive SMS and/or email messages
notifying them when an alarm was aborted and
that the central monitoring station was not noti-
fied.
By default, Verify contacts
are notified by SMS and
email when an alarm is dis-
armed during the Alarm
Transmission Delay period.
Cancel Window
For five minutes after the end of the Abort Win-
dow the customer can disarm the system to send
an Alarm Cancel to the central monitoring station.
This feature is not con-
figurable.
Use of Duress Fea-
ture
A four-digit code that immediately sends a silent
alarm when used to arm/disarm the system or
access security settings. Otherwise, this works the
same as the Master keypad code. Alarms sent
from use of the Duress Feature are not recorded in
the TouchScreen history, however, they do
appear in the history on the Management Portal.
Default: Duress Code is dis-
abled.
Duress Code
Must be unique and created by the user.
Default Duress Code: Null
Cross Zoning
Two security zones that only trip alarm if they are
both faulted within configured period of time. Can
only be created after the security zones have been
added in a separate step.
Default: 10 seconds
Range: 1 second to 999 sec-
onds
Swinger Shutdown
After the TouchScreen has sent an alarm the set
number of times (trips) to the central monitoring
station, no more alarms are sent to the central
monitoring station for 48 hours or until the secu-
rity system is disarmed.
Default: 2 trip
Range: 1 to 6 trips
Fire Alarm Ver-
ification
When enabled, the central monitoring station
only contacts the authorities when multiple
smoke detectors are faulted OR one detector is in
an alarm for 60 seconds.
Default: Disabled
Call Waiting
The TouchScreen connects to the central monitoring station over broadband and
cellular, no call waiting alert is required.
System Test
Perform the system test as described in
Step M: Testing the Alarm Functionality