Rosslare Enterprises Ltd AYR6255 Benutzerhandbuch
Technical Specifications
8
AY-R6255 Installation and Operation Manual
2.
Technical Specifications
Electrical Characteristics
Power Supply Type
Linear (recommended)
Operating Voltage Range
12–16 VDC
Maximum Input Current
Standby: 100 mA
Read: 250 mA
Read: 250 mA
Tamper Output
Open collector, active low, max. sink
current 16 mA
current 16 mA
Read Range* (max)
MIFARE Classic EV1®: 7 cm (2.8 in.)
Felica/MIFARE Plus®/DESFire®: 3 cm
Felica/MIFARE Plus®/DESFire®: 3 cm
(1.2 in.)
ISO1443B: 5 cm (2.0 in.)
China ID: 2 cm (0.8 in.)
ISO1443B: 5 cm (2.0 in.)
China ID: 2 cm (0.8 in.)
Maximum Cable Distance to
Controller
Controller
150 m (500 ft)
RE Modulation
ASK @ 13.56 MHz
Output Format
Wiegand 26-Bit, Wiegand 32-Bit,
Wiegand 34-Bit, Wiegand 40-Bit
Wiegand 34-Bit, Wiegand 40-Bit
Environmental Characteristics
Operating Temp. Range
-31°C to 63°C (-25°F to 145°F)
Operating Humidity Range
0 to 95% (non-condensing)
Physical Characteristics
Height x Width x Depth
120 x 89 x 21 mm
(4.7 x 3.5 x 0.8 in.)
(4.7 x 3.5 x 0.8 in.)
Weight
202 g (7.1 oz)
* Measured using a Rosslare proximity card or equivalent. Range also depends
on electrical environment and proximity to metal.