Rosslare Enterprises Ltd DRU955BT Benutzerhandbuch

Seite von 2
DR-U955BT 
 
Multi-format Desktop Reader 
User Manual 
1.  Introduction 
The DR-U955BT is an advanced desktop reader for MIFARE Classic
®
 
EV1, MIFARE
®
 DESFire
®
 EV1, UHF, and BLE. It reads the ID data of 
the credential, and transmits the relevant ID data to any connected 
access control software, such as Rosslare’s AxTraxNG™. 
It has a slim and attractive design and is built for convenience and 
portability. With its USB computer interface, it is quick and easy to 
install and runs without any additional power source. 
Using the BLE-Admin or BLE-ID apps, the reader can function like 
other Rosslare BLE readers and can transmit the BLE ID to the 
reader. 
The Hardware Configuration Tool (HCT) can be used to configure 
the reader’s specifications, such as the Wiegand format used. 
The reader reads the CSN ID of each credential (MIFARE, UHF, BLE) 
and transmits it to the software with the bit length pre-configured by 
the user. 
Figure 1: DR-U955BT 
 
2.  Technical Specifications 
2.1 
Electrical Characteristics 
Operating Voltage Range 
5 VDC (USB powered) 
Standby Current 
250 mA 
Max. Operation Current 
300 mA 
Supported Transponders 
MIFARE, UHF, BLE 
Read Card Distance 
UHF and MIFARE: Up to 5 cm (2 in.) 
BLE: Up to 6 m (19.7 ft) 
Operation Frequency 
  RFID: 13.56 MHz  
  DR-U955BT US: 902–928 MHz 
(America) RFID 
  DR-U955BT EU: 865–868 MHz 
(Europe) RFID 
  Bluetooth: 2.402-2.480 GHz 
Output Formats 
Supports Wiegand 26-Bit to 64-Bit 
2.2 
Environmental Characteristics 
Operating Environment 
Indoor use 
Operating Temperature Range 
 
Storage Temperature Range 
-20°C to 63°C (-4°F to 145°F) 
Relative Humidity Range 
0 to 95% (non-condensing) 
2.3 
Physical Characteristics 
Weight 
130 g (4.6 oz) 
Dimensions (L x W x H) 
123 x 70 x 16.2 mm (4.9 x 2.8 x 0.6 in.) 
3.  Operation
The DR-U955BT appears as a COM port device when plugged in to a 
PC and can be used for any application. When a card is presented to 
the reader, the reader outputs the Wiegand ID data on the COM port 
only once until a new card is presented. 
You must use the AxTraxNG software to enroll cards. Please refer to 
the relevant appendix in the AxTraxNG™ Software Installation and 
User Manual
For the enrollment reader to function in AxTraxNG, you must know 
the COM port being used. The COM port can be found in Microsoft 
Device Management’s driver details under ‘Ports (COM & LPT)’. The 
port being used appears as “USB serial Port (COMx)”, where x is the 
number of the port used. 
 
S M A R T