Installer Menu 
HLX-24 Hardware Installation and Programming Manual 
37 
 
For a signal to be sent to the CMS, the Alerts reporting group must be enabled 
in Report Options (Section 
To set the Alarm Cancel: 
1.
  Using the numeric keypad, set the alarm cancel time between 01 to 10 
minutes or 00 to disable the option. 
2.
  Press Enter to confirm. 
6.4.19
  Alarm Abort Time 
The system sounds a warning, but the central station does not receive 
notification of the alarm if the user disarms the system within the specified 
alarm abort time. This function applies to interior, perimeter, and 24-hour 
zones. The default 
Alarm Abort Time
 is 30 seconds. 
To set the alarm abort time: 
1.
  Using the numeric keypad, set the alarm abort time between 01 to 45 
seconds or 00 to disable the option. 
2.
  Press Enter to confirm. 
6.4.20
  Backlight Time 
Specifies the backlight options; by default, the backlight time is set to 15 
seconds. 
To set the backlight: 
1.
  Using Menu, select one of the following options: 
 
Always: to specify that the keypad and buttons are backlit at all 
times. 
 
15 secs: to specify that the keypad and buttons are backlit for up to 
15 seconds after last key press. 
2.
  Press Enter to confirm. 
6.4.21
  Hide Display 
Enables you to specify that when armed, the system does not display the 
system statuses or other system prompts; by default, 
Hide Display 
is off. 
To display the system status: 
1.
  Using Menu, select one of the following options: 
 
Off to display status and prompts. 
 
On to hide status and prompts. 
2.
  Press Enter to confirm.