1.  General Description 
The SA-29G is a high performance, supervised, wireless 
repeater for Rosslare's Millennium Wireless Security 
product line. SA-29G is compatible with a wide variety of 
wireless control panels, universal receivers, RF sensors, 
and remote controls. 
Note 1: This product must be installed professionally, and 
has only one available channel. 
Note 2: Pursuant to FCC §15.21 [54FR 17714, Apr.  25, 
1989, as amended at 68 FR 68545, Dec. 9, 2003), changes 
or modifications made to equipment which are not 
expressly approved by Rosslare Enterprises, Ltd., may void 
the user’s authority to operate the quipment.  
1.1. Standard Features 
1)  Integral rechargeable battery - provides up to 10 hours 
(UPS) backup power with up to 10 years standby 
battery life. 
2)  Supervision signal - transmitted every 20 minutes.  
3)  Case Tamper and optional Back Tamper. 
4)  Advanced microelectronics for ultra-low current 
consumption. 
2.  Technical Specifications 
2.1. Electrical Characteristics 
Primary Power Supply: +12V DC (+) Linear regulated; (-) 
GND: two terminal blocks. 
Backup Power Supply: UPS Rechargeable Lithium-Ion 
Battery: 4.2 Volt 1600 mAh 
Current Consumption: DC Powered Standby - 14.5 mA  
                                       DC Powered Transmit - 29 mA  
                                       Battery Powered Standby - 7.5 mA  
                                       Battery Powered Transmit - 20 mA 
2.2. Environmental Characteristics 
Operating Temperature: -5°C to +50°C (-23°F to +122°F) 
Operating Humidity: Up to 95% non-condensing (max.) 
RF Receiving Sensitivity: 
The integrated wireless receiver is 
rated at -111 dBm sensitivity for receiving incoming RF 
signals; 180 meters- Open Field 
RF Transmission Output Power: SA-29G - up to 10 mW or 10 
dBm; 200 m (approx 600 feet) - Open Field 
RF Transmission Frequency: 
433.92 or 868.35 MHz 
Cover Tamper Switch: Detects the removal of the SA-29G 
front cover. 
Back Tamper Switch: Detects the removal of the SA-29G 
from the wall (optional using Jumper). 
Supervisor: The supervisory signal is routinely transmitted to 
the control panel every 20 minutes, advising the Tamper 
Status, Battery Status, and Event Activation Status. 
2.3. Physical Characteristics 
Dimensions: 100mm x 76mm x 27mm (3.93in. X 2.99in x 
1.062in) 
Weight: 116 grams (4.09 oz) 
3.  Installation – General Information 
The SA-29G Repeater detects the RF transmissions from 
the Rosslare sensors and remote controls in its vicinity, 
and re-transmits them to the main control unit. 
Caution: AVOID mounting on or near large metal 
surfaces or reinforced concrete walls which may interfere 
or block the wireless signals. Test the range from the 
desired location using the RF test procedure described in 
section  0.  
Caution: To prevent false tamper signals, make sure that 
after enrolling the repeater, the Case and Back Tamper 
are secure. 
Caution: BATTERY WARNING!!! DO NOT REMOVE, DE-
SOLDER, SHORT-CIRCUIT OR BURN THE BATTERY ON THE 
UNIT. THIS MAY CAUSE PERMANENT DAMAGE TO THE 
BATTERY. 
4.  Installation Instructions 
4.1. Recharging the Battery 
Recharge the battery the first time you operate the SA-
29G, or if you are using the unit after it has been out of 
service for a prolonged period of time. 
Recharge the UPS battery for at least 7 hours, to make it 
fully functional. 
4.2. Enrolling to the Host Control Panel 
1)  In the appropriate RF zone, enter the programming 
menu of the host. Go to the Repeater Zone and select 
the RF device.  
2)  When prompted, generate a transmission from the SA-
29G Repeater unit using the cover Tamper Switch (the 
SA-29G must be connected to DC power).  
Note: The SA-29G will identify any Rosslare wireless 
product, by protocol. It will repeat any transmission it 
receives so the transmission reaches other devices that 
are part of the setup (e.g., Wireless Keypads, Control 
Panels and/or Wireless Sirens).  
 
4.3. Mounting the SA-29G onto the Wall  
1)  Remove the plastic screw cover from the SA-29G front 
cover (see Figure 1), to reveal the case-locking screw. 
2)  Unscrew the case locking screw and remove the front 
cover.  
CAUTION: Do not touch any of the circuitry.  
3)  Using the back case as a template, mark the locations 
of the holes on the wall, and then drill the desired 
holes. It is recommended to install the unit in a high 
position to prevent tampering.