Troubleshooting
If the scanner is not working, investigate the following:
Is the unit on?
Check that the bar code symbology being scanned is enabled for the hand-held you are 
using. Check any other parameters that affect the scanning procedure or the bar code.
Check the bar code to make sure it is not damaged. Try scanning a different bar code to 
verify that the problem is not with the bar code.
Check that the bar code is within the proper range.
Does the hand-held display the warning without scanning? This suggests a hardware 
problem in the hand-held.
Is the laser beam scanning across the bar code? 
Once the scan beam has stopped, check the scanner window for dirt or fogging.
3.6.4
Operating One Dimensional (1D) Internal Laser Scanners
Turn the hand-held on. Wait until the unit has booted up completely.
Aim at the bar code and press the scan key or the trigger. A scan beam and a warning 
indicator appear until a successful decode is achieved or six seconds have elapsed. 
3.6.5
Operating Internal PDF Laser Scanners
This scanner decodes PDF417 two-dimensional bar codes.
Turn the hand-held on. Wait until the unit has booted up completely.
Aim at the bar code and press the scan key or the trigger. The beam expands into a rec-
tangle covering the bar code to properly scan it. The scan beam and a warning indicator 
are visible until a successful decode is achieved or three seconds have elapsed.
Important: If an aiming dot is available on the installed scanner, the dot will be enabled 
for a configurable time period (including off), after which normal scanning 
begins. Refer to “Dot Time (msec)” on page C-8 for details. 
Double-clicking the trigger will override the aiming delay and initiate an 
immediate scan. Note that the aiming dot is standard on long-range and 
high visibility internal scanners.