Secondary Range Performance Data 
The following table describes the indoor and outdoor ranges recorded with the TXR series of 2.4Ghz transceivers. 
Table 2 INNCOM I5RF Radio Indoor Range 
Transmitter 
Receiver 
Receiver 
Receiver 
 
02-9994 
02-9894 
02-9927 
02-9994 
70ft (21m) 
73ft (22m) 
98ft (30m) 
Table 3 INNCOM I5RF Radio Outdoor Range 
Transmitter 
Receiver 
Receiver 
Receiver 
 
02-9994 
02-9894 
02-9927 
02-9994 
540ft (165m) 
570ft (174m) 
654ft (199m) 
02-9894 
640ft (195m) 
980ft+ (299m+) 
768ft (234m) 
02-9927 
550ft (168m) 
620ft (189m) 
980ft+ (299m+) 
202-515 (I5RF) 
540ft (165m) 
Table 4 INNCOM I5RF Operating Conditions 
Parameter 
Min 
Max 
Unit 
Operating ambient temperature range 
-40 
85 
°C 
Operating supply voltage 
2.0 
3.6 
The supply pins to the radio must be driven by the 1.8VDC on-chip voltage regulator. 
Table 5 INNCOM I5RF Safety / Regulatory 
Agency Approval 
Specification 
Status 
FCC
 
15.249
 
202-515 Certified under FCC ID: GTC202515I5RF
 
Only approved antennas can be used with this module.  Additional antennas would require an application filing 
with the FCC in order to have them approved.  Antennas which have either a higher gain or are of a different 
type may not be used, with this module, unless additional certification is obtained. 
"
All Final Products containing the INNCOM I5RF 202-515 module must contain the following statements on their 
label:"   
This device contains FCC ID: GTC202515I5RF. The I5RF radio is only to be used in INNCOM products. 
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This 
device may not cause harmful interference, and (2) this device must accept any interference received, including 
interference that may cause undesired operation. 
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a 
residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not 
installed and used in accordance with the instructions, may cause harmful interference to radio communications. 
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does 
cause harmful interference to radio or television reception, which can be determined by turning the equipment off 
and on, the user is encouraged to try to correct the interference by one of the following measures: