Climax Technology Co Ltd CO8 Benutzerhandbuch

Seite von 3
 
 
 
Carbon Monoxide Detector   
(CO-8, CO-8F1)
   
 
 
Parts Identification 
1. Dual Color LED (Amber & Red) 
 
When the battery voltage is low, the Amber LED will flash every 
30 sec. 
 
While the Carbon Monoxide Detector is transmitting signal, the 
RED LED will flash 
 
While  Carbon  Monoxide  is  alarming,  the  Red  LED  will  flash 
quickly. 
2. Learn/Test Button 
Press the button to: 
 
Transmit  a  learn/test  signal  for  device  learning  or  radio  range 
test. 
 
To silence alarm temporarily after alarm activation. 
3. Battery Compartment Cover 
4. Mounting Holes 
5. Mounting Bracket 
 
 
Battery 
 
3 “AA” 1.5V alkaline batteries are used to supply power.   
 
The Carbon Monoxide Detector has a battery life of approximately 1.8 years. 
 
When  Carbon  Monoxide  Detector  detects  low  battery  voltage,  a  low  battery  signal  will  be 
transmitted along with regular signal transmissions. The Amber LED will flash and the Carbon 
Monoxide Detector will emit a beep every 30 seconds. 
 
When  battery  is  exhausted,  remove  the  battery  compartment  cover  and  replace  with  new 
batteries. 
 
 
Supervision 
 
After installation, the Carbon Monoxide Detector will automatically transmit Supervisory Signals 
periodically to the Control Panel at intervals of 30 min. to 50 min. randomly. 
 
If the Control Panel has not received the signal from the Carbon Monoxide Detector for a preset 
period  of  time,  the  Control  Panel  will  determine  the  Carbon  Monoxide  Detector  has  failed 
supervision and is out-of-order. 
 
 
Carbon Monoxide Detection 
 
The  alarm  will  be  activated  after  CO  concentration  is  detected  according  to  time  length  in 
following table: 
CO concentration 
level 
Time taken before 
alarming 
30 ppm 
N/A 
50 ppm 
60~90 minutes 
100 ppm 
10~40 minutes 
300 ppm 
Under 3 minutes