28 
„  If both Digital and Speech Alarm 
reporting are set, the reporting call 
sequence will
 
only be terminated 
once one Digital reporting (any of CID, 
Scancom or Tunstall protocols) and 
one Speech reporting are answered 
successfully. 
„  There is a calling pause between 
each call. For different Tel. Numbers, 
the pause is set as 5 secs, and for 
same Tel. Number, it is set as 62 secs. 
 
Retry Method: 
¾ 
Retry Circle: Each Tel. Phone number 
can be retried up to 5 times alternative; 
and max. 15 calls will be retried.  During 
the retry period, the Red LED still stays on 
steadily, while the Red Help Button 
backlight dims. 
¾  In the retry circle, if any digital, voice 
message, or speech reporting fails, CTC-
1052RV Pro makes a 10-min pause, then 
starts another 15-call retry circle, followed 
by another 10-min pause. This cycle 
repeats until all reporting is/are answered 
successfully. 
¾  During the 10-min pause, CTC-1052RV 
Pro returns to normal mode with Red LED 
on:  
‹ 
Press the Green reset button to 
terminate the reporting. 
‹ 
If new event happens, CTC-1052RV 
Pro starts the reporting immediately. 
If an alarm is triggered by Talking Pendant 
(WTRV/ WTRVS): 
„  For Tel number(s) set as Digital 
Method (set by Command #20-
24), the WTRV will wait for 
Central Monitoring Station’s 
DTMF command after digital 
reporting is complete. 
„  For Tel number(s) set as Speech 
Method (set by Command #20-
24), the WTRV/ WTRVS will open 
a remote two-way voice 
communication. 
 
 
 
 
4.4. Walk Test (Range Test) 
Put CTC-1052RV in Learning Mode to 
determine the operation range of the devices. 
Step 1.  From Idle mode, press and hold the 
RESET button for 6 seconds. 
Step 2.  Once pressed, a button beep sound 
will be heard. CTC-1052RV will emit 
one short beep at 3 sec., then a 
double beep when it reaches 6 sec. 
Step 3.  Release the button after you heard the 
double beep. Then, a short beep will 
be heard indicating CTC-1052RV is 
now in Learning Mode. The RED 
LED
 begins to flash. 
Step 4.  Move the device to your desirable 
location in the house, and press the 
TEST button to observe the range for 
its operation. 
Step 5. If CTC-1052RV responds with one 
long beep, then the particular device is 
within the operation range. 
<
<
N
N
O
O
T
T
E
E
>
>
 
 
For Talking Pendant WTRV/ WTRVS: 
During Walk Test, when the Pendant 
button is pressed you will hear WTRV/ 
WTRVS emit beep (1s-on / 1s-off). After 
about 3 sec, the Control Panel will emit a 
long beep. About 2 sec later, the Control 
Panel will emit a long beep again, 
indicating the Pendant is within the 
operating range. If you do not hear beeps 
emitted by Control panel, turn the Pedant 
off and repeat the steps mentioned above 
until you hear the Panel beeps. 
Step 6.  To exit Learning Mode, press both 
RESET 
& HELP buttons 
simultaneously. Or, CTC-1052RV will 
exit Learning mode automatically after 
5 mins of inactivity.  
 
4.5. Global Test 
Global Test is used to test if the complete 
system is working properly.  
 
To do the Global Test: 
Step 1. Press the RESET button once. 
Step 
2. Within 5 secs, press Pendant 
button.  
Step 3.  CTC-1052RV will emit a short 
beep and report to Monitoring