Climax Technology Co Ltd G4MR Benutzerhandbuch

Seite von 10
 
1
INSTALLATION GUIDE 
z  SYSTEM INTRODUCTION 
The Locator system includes the following components: 
Locator (LT-49): 
The Locator receives 433 MHZ signal sent from WTR and transmits 
the signal in 912 MHZ to Repeater (RPN-99) or Base Unit 
(BUN-152). 
Repeater (RPN-99):  (Optional) The Repeater is an optional device used to relay signal 
sent from Locator with same Group number and System ID in 912 
MHZ. 
Base Unit (BUN-152): The Base Unit receives the signals sent from Locator or Repeater in 
912 MHZ and forward the signal to PSTN Dialer via RS232 
connection 
z  SYSTEM OPERATION DIAGRAM 
 
z  SYSTEM CAPABILITY: 
z  Each system can have maximum of 4096 LT-49 and 4096 RPN-99.   
z  Each Locator and Repeater has its own ID Code set by a 12-pin Dip Switch. 
z  The frequency hopping technology is adopted in the communication between 
Locator, Repeater and BUN-152.   
z  There are three groups of hopping frequency bands are available. Each group 
contains 25 channels: 
GROUP 1: 906.26 ~ 914.90 MHZ, 25 channels 
GROUP 2: 906.38 ~ 915.02 MHZ, 25 channels 
GROUP 3: 906.50 ~ 915.14 MHZ, 25 channels 
z  Make sure the distance between BUN-152, RPN-99 and LT-49 is greater than 5 
meters. If the distance is too close, the signal may interfere with each other. 
DEC-31.-2013