IDENTIFYING THE PARTS   
 TOP VIEW: 
1)  Red LED 
This Red LED is used for indicating different operation 
status of VCM. 
- When the LED is OFF, the system is in Normal 
operation mode. 
- When the LED is ON,  the system is in Learn Mode for 
additing/deleting devices or motor. 
- When the LED is Flashing in duty cycle, the device is 
out-of-order. 
- When the LED is Flashing quickly, the VCM is 
transmitting signals.   
 
REAR VIEW: 
2)  DC Jack 
For connecting the DC 6V 2A power adaptor. 
 
3)  Rock Switch (3 way) 
This Rock Switch is used to manually open/close the 
valve control.    When the switch is slid either upward 
or downward and released, it will automatically return 
to central position. 
Slide UPWARDS:   
to Open the Valve control 
In Central position:    Valve control is in Stand-by mode 
Slide DOWNWARDS:   to Close the Valve control 
     
 
<NOTE> 
 
"
 The up and down direction is marked by arrow indication on the side of VCM plastic cover.     
 
4)  Red Tack Switch   
This Red Tack Switch is used for Device or Motor Learning, Removing Fault Device and Resetting 
the System to Factory Default.   
a) With 1 press only: 
  it will transmit a test signal to Dialer; Red LED flashes quickly during the transmission. 
¾ 
for one-way radio transmission: beep once 
¾ 
for two-way radio transmission: beep once only if the panel receives confirmation from VCM 
b) Press and hold for 5 secs: 
  for entering Device learning process 
c) Press and hold for 10 secs: 
  for entering Motor learning process 
d) Press and hold for 15 secs: 
1
5