Advance Security Inc R30 Benutzerhandbuch

Seite von 10
00/04/21
MODEL  6974
REMOTE CONTROL AUTO ALARM SYSTEM
INSTALLATION & OPERATION INSTRUCTIONS
Override Plug
 L.E.D. Plug
4 pin shock sensor
11 Pin Plug
Antenna Plug
1. Blue/yellow (N/O)--unlock.
2. Blue/red (N/C)--unlock.
3. Blue/white (Com)--unlock.
4. Green/white (Com)--lock.
5. Green/yellow (N/O)--lock.
6. Green/red (N/C)--lock.
Negative door lock.
Green/white
Blue/white
Green/yellow
Blue/yellow
Positive door lock.
Green/white
Blue/white
Green/yellow
Blue/yellow
Door lock
Door unlock
Master
locking
switch
locking
Master
switch
+12V
Door lock
Door unlock
+12V
10 Pin main harness
2 wires start cut
3 A Fuse
Red Wire: +12V To Fuse Box
Brown Wire: To Siren
Black Wire: To Ground
Gray Wire:Channel 2 (Trunk release) power
Red / White Wire: Parking light power
Parking light
Yellow Wire: To Ignition Switch
+12
White wire :Parking Light Output
Light green wire :Dome Light Output
Light green wire :Dome Light power
10A Fuse
Entry illumination
Connect to +12V for + switch
or to ground for - switch
Existing door pin switch
Dome Light
Trunk release
Connect to +12V for + switch
or to ground for - switch
Gray Wire:Channel 2 (Trunk release) output
Connect to active
trunk release button