Tyco Safety Products/Sensormatic AMS1140 Benutzerhandbuch

Seite von 15
 
Preliminary 
AMS-1140 DETECTORS 
8200-2684-02, REV. 0 
SETUP AND SERVICE GUIDE 
1 of 15
 
AMS-1140 Detectors 
Setup and Service Guide 
 
ZA1140-D 
Contents 
About this Guide .................................................... 1
 
Detector Service Features ..................................... 1
 
Circuit Board Pinouts ............................................. 3
 
Service Procedures ............................................... 3
 
Field Replaceable Units .................................. 3
 
Replacing the Secondary Cap Board .............. 3
 
Replacing the Interconnect Cable ................... 4
 
Installing the Pedestal Installation Kit .............. 5
 
Replacing the Alarm Board and Lens ............. 6
 
Replacing the Fuse ......................................... 7
 
Inhibiting the Transmitter ................................. 7
 
Using the Software Configurator ..................... 7
 
Connecting to AC Power ................................. 8
 
Tuning the Pedestals ...................................... 9
 
Troubleshooting ................................................... 10
 
Checking Detector Operation ........................ 10
 
Dead system/Low sensitivity ......................... 10
 
False Alarms ................................................. 11
 
Understanding Error Codes .......................... 11
 
Interpreting LED Indicators ........................... 12
 
Specifications ....................................................... 15
 
Declarations ......................................................... 15
 
 
 
© 2010 Sensormatic Electronics LLC 
About this Guide 
This guide explains how to tune, service, and 
troubleshoot AMS-1140 detectors. Related 
documents are: 
  Installation Guide, AMS-1140 Detector, 8200-
2684-01 
Detector Service Features 
AMS-1140 detectors have the following service-
related features: 
  Power on self-test. Upon power up or 
hardware reset, detector software runs a self-
test to ensure it functions.  
  Diagnostics. You use a laptop computer and 
configuration software to set up and configure 
the detector, and to determine its operational 
status. The detector also has an LED (DS5) 
inside the primary pedestal that flashes an error 
code if system software should fail. 
  Alarm indication. The top cap of the primary 
pedestal contains flashing LEDs; the base 
cover of the primary pedestal contains a piezo 
for an audio alarm. The volume of the audio 
alarm is controlled with a pot (RV3) on the main 
circuit board in the primary base cover. 
  Transmit inhibit. The base of the primary 
pedestal has a hole that provides access to a 
transmit-inhibit pushbutton.  
  Tags Too Close indication. If this feature is 
enabled by the configurator, the pedestal will 
flash a unique alarm pattern when a non-
deactivated label or tag is left in the detection 
field of the detector for awhile. 
  Adjacent transmitter interference reduction
This feature allows service to adjust the Energy 
Trim Level to decrease the impact of electronic 
noise from nearby anti-theft systems. 
  Backfield reduction. If enabled by the 
configurator, the detector will reduce the size of 
the detection field behind the pedestals.  
  Simplified design. AMS-1140 detectors are a 
simplified design and do not support the 
following features or options: people-counting, 
relays, auto-phase, wired sync, jammer detect, 
auxiliary receivers, remote alarms and external 
alarm counters.