Tait Limited TBA8K2 Benutzerhandbuch
36
Power Amplifier and Transmitter Specifications
TB8100 Specifications Manual
© Tait Electronics Limited October 2004
Radiated Spurious Emissions
Transmit - B, C and H Bands
Transmit - K Band
Standby
Standby
<–36dBm to 1GHz
<–30dBm 1GHz to 4GHz
<–20dBm to 9GHz
<–57dBm to 1GHz
<–47dBm 1GHz to 4GHz
<–30dBm 1GHz to 4GHz
<–20dBm to 9GHz
<–57dBm to 1GHz
<–47dBm 1GHz to 4GHz
Conducted Spurious Emissions
Transmit - B, C and H Bands
Transmit - K Band
Standby
Standby
<–36dBm to 1GHz
<–30dBm 1GHz to 12.75GHz
<–20dBm to 9GHz
<–57dBm to 1GHz
<–47dBm 1GHz to 12.75GHz
<–30dBm 1GHz to 12.75GHz
<–20dBm to 9GHz
<–57dBm to 1GHz
<–47dBm 1GHz to 12.75GHz
Transmitter Switching - B, C and H Bands
complies with EN 300 113-1 v1.4.1 and EN 300 113-2
(03/2001)
(03/2001)
Transmit Key Time*
Key Up
5W PA
50 and 100W PAs
50 and 100W PAs
Key Up Debounce Timer
Key Down
Key Down
5W PA
50 and 100W PAs
50 and 100W PAs
Key Down Debounce Timer
*with VCO in lock
≤2.5ms
≤2ms
20ms
≤2ms
20ms
≤2.5ms
≤2ms
20ms
≤2ms
20ms
Continuous Repetitive Key Rate
24Hz maximum
Lock Time
≤20ms
Transmitter RF Section (Continued)
Control and Monitoring
Control Inputs and Outputs
I
2
C data, clock and ground
PA key line input
fan control output
fan control output
Monitor Outputs*
Permanently Assigned
Selectable**
*analogue
**select one
**select one
forward power
reverse power
ambient temperature
RF power control voltage
reverse power
ambient temperature
RF power control voltage