This chapter describes how to install the TB8100 BSS in a standard 19 inch 
rack or cabinet.  It also provides some general information on safety 
precautions and site requirements.  We recommend that you read the entire 
chapter before beginning the installation.
5.1
Personal Safety
Lethal Voltages
Warning!!
The PMU contains voltages that may be lethal.  
Refer to the ratings label on the rear of the 
module.
The TB8100 BSS must be installed so that the rear of the PMU is located 
in a service access area.  
Disconnect the mains IEC connector and wait for five minutes for 
the internal voltages to self-discharge before dismantling.  The AC 
power on/off switch does not isolate the PMU from the mains.  It 
breaks only the phase circuit, not the neutral.
The PMU should be serviced only by qualified technicians.  All servicing 
should be carried out only when the PMU is powered through a mains 
isolating transformer of sufficient rating.  We strongly recommend that 
the mains power to the whole of the repair and test area is supplied via an 
earth leakage circuit breaker.
Explosive Environments
Warning!!
Do not operate TB8100 BSS equipment near 
electrical blasting caps or in an explosive atmos-
phere.  Operating the equipment in these envi-
ronments is a definite safety hazard.
Proximity to RF Transmissions
Do not operate the transmitter when someone is standing within 90 cm (3ft) 
of the antenna.  Do not operate the transmitter unless you have checked that 
all RF connectors are secure.