Digital Monitoring Products Inc PC0131 Benutzerhandbuch

Seite von 22
 
7800 Series Keypad Installation Guide 
9
PRELIMINAR
Y
Programming Keypad Options
Kpd Kpd
Opt diag 
  StOp
 
Keypad Options (KPD OPT) 
To program keypad options, press KPD OPT.  
CUrrent Keypad
addreSS: 01
 
Keypad Address
Set the keypad address from 01 to 05 with the XT30, XT50, 
XR100 and 01 to 16 with the XR500 Series.  The default 
address is set at 01.  To change the current address, touch 
the address display and enter the new address.  It is not 
necessary to enter a leading zero for addresses 01 to 09.
Keypad MOde:
*SUp 
 
 
UnSUp
  Keypad Type
Configure the keypad for either Supervised or Unsupervised 
operation.  Keypads with zones connected to them must be 
supervised and cannot share an address with other keypads.  
Unsupervised keypads can operate together sharing the same 
address.  Zones cannot be used on unsupervised keypads.  
To change the current setting, press the SUP or UNSUP.  An 
asterisk appears next to the selected option.
Note: Unsupervised addresses cannot be used when Device 
Fail Output has a programmed value other than zero. 
arM paniC KeyS:
*pn  *eM  *Fi
 
Arm Panic Keys
Use this option to configure the Panic Icons.  To enable 
or disable a Panic Icon, touch the icon name: PN (Panic), 
EM (Emergency), and FI (Fire).  Once the panic icon is 
enabled, an asterisk displays next to the description and 
the respective Panic icons display for the user.  Refer to the 
Panic Icon Options section in this document.
SySteM
area a/p h/a hSa
  System Mode
Configure the keypad as the same system type selected in 
System Options panel programming.  Select HSA when zones 
are assigned to Bedrooms for the Sleep area to be active. 
CLOSing COde
  
  nO  yeS
 
Closing Code
 
Configure the keypad for the same operation as selected in 
panel programming.  When 
YES is selected, a code number 
is required for system arming.  If 
NO is selected, a code 
number is not required for system arming.  Default is 
NO.
ShOrtCUt Key x:
reSet
 
Shortcut Keys
Use these options to configure up to three shortcut icons to 
display at the bottom of the arming and panic screens.   Key 
1 default is RESET, Key 2 default is CHIME and  Key 3 default 
is NONE.
 
RST (Reset) 
Sensor (Fire) Reset on all systems 
CHM (Chime) 
Monitor on all systems
CHK (Checkin)  Check-in report on XT Series systems
 
EXIT (Easy Exit) Easy Exit for XT Series Home/Away systems
 
NONE 
No shortcut key displayed
ShOrtCUt Key x:
rSt ChM ChK exit
ShOrtCUt Key x:
nOne