Digital Monitoring Products Inc PC0163 Benutzerhandbuch

Seite von 40
CellComSL
 
Series Universal Communicator Installation and Programming Guide 
Digital Monitoring Products
7
remote armIng/dIsarmIng
Remote Arming/Disarming
4.1 
DMP Virtual Keypad App / Virtual Keypad Browser
Using a Smartphone with the DMP Virtual Keypad App or using a computer with the Virtual Keypad Browser  
(www.myvirtualkeypad.com), you can connect to the CellComSL Series Communicator to arm Areas, turn Outputs
on and off, and add, edit or remove Users. When using the CellComSLCZ, you can control Z-Wave devices,
Favorites and Rooms.
Figure 12: Virtual Keypad Application can be used to access the CellComSL Series Communicator.
A burglary control panel zone may be programmed as an arming zone and connected to a CellComSL output
(O1 or O2) (See Figure 13). Program the output number in Armed Output or Remote Arming Output in Output
Options of the CellComSL (See Armed Output or Remote Arming Output). The CellComSL Communicator output
connections can be used with any of the applications listed in Applications Section.
Use 18-22 AWG for 
Power Supply connection
O1
O2
12 Vdc Aux. Output
+
-
 Control Panel 
B
AT
MODEL CellComSL
PROG
+12
G
Z1
Z2
Z4-
Z4+
G
Z3
R
T
O2
O1
R
B
GND
Zone 1
Zone 2
Control Panel EOL resistor
Figure 13:  Burglary control panel zones connected to the CellComSL Series outputs to 
arm and disarm the burglary control panel.