Digital Monitoring Products Inc PC0163 Benutzerhandbuch

Seite von 40
CellComSL
 
Series Universal Communicator Installation and Programming Guide 
Digital Monitoring Products
1
IntroductIon
CellComSL™ Series Universal Alarm Communicator
Description
The CellComSL™ Series Alarm Communicator provides a fully supervised alarm communication path for any
burglary or residential fire control panel. The CellComSL Series can be connected to a control panel’s dialer
output and used to capture Contact ID messages
based on SIA DC-05-1999.09-DCS. The CellComSLC has a
built-in CDMA cellular module to send messages to DMP Model SCS-1R or SCS-VR Central Station Receivers. The
communicator also provides four input zones and two open-collector outputs for connection to burglary or 
residential fire control panel outputs and zones. The CellComSL Series Communicator Zone 4 allows a connection
to the bell output of an existing burglary control panel. The communicator operates in a variety of applications: 
CID Dialer Connection, Zones 1-4 Input Connections, or Zone 4 Bell Connection (See Applications on page 5). The
CellComSLCZ™ Alarm Communicator includes an onboard Z-Wave controller for home automation applications.
What is Included
The CellComSL Series Universal Alarm Communicator includes the following:
•  PCB with Enclosure
•  3.7 Vdc 800 mAh Lithium Ion System Battery
•  Hardware Pack
System Components
1.1 
Terminals (J9)
Power Connection Terminals
Power is provided from the Nominal 12 Vdc auxiliary output of the burglary control panel.
OBSERVE POLARITY (See Figure 1 and Backlit Logo)
Using 18 - 22 AWG wire, connect the communicator terminal +12 to the positive terminal on the control panel 
auxiliary output.
Connect the communicator terminal G (Ground) to the negative terminal on the control panel auxiliary output.
Control Panel Standby Power
During a power outage, the CellComSL draws power from the control panel’s backup battery. The CellComSL must
be included in the standby battery calculations for the control panel.
Zones 1-4
Terminals Z1 to Z3, G (Ground), Z4+ and Z4- provide four zones to connect to individual relay outputs on
the control panel. Zone 4 (Z4+ and Z4-) can be connected to the control panel bell output. See Zone 4 Bell
Connection.
Open-Collector Outputs
The two outputs, terminals O1 and O2 (see Figure 1), can be programmed to indicate the activity of the zones
Figure 1: CellComSL Series Communicator
R
B
J8
S3
J9
RESET
LOAD
S1
S2
J19
J26
system components