Digital Monitoring Products Inc PC0181 Benutzerhandbuch
Digital Monitoring Products
XTLplus Installation and Programming Guide
34
ZONE INFORMATION
turn a panic or pendant LED on during normal operation. Select NO to turn the LED
off during normal operation. The LED always operates on all transmitters when the
transmitter case is open and the tamper is faulted. Default is YES.
33.8.5
Disarm/Disable
Select YES to disable the zone tripped message from an 1103 Universal Transmitter
(Version 107 or higher software) or 1126/1127 PIRs during the disarmed period.
When disarmed, the transmitter or PIR only sends supervision, tamper, and low
battery messages to extend transmitter battery life. For 1103 Transmitters, a zone
tripped message is sent if the zone remains tripped for 20 seconds. Leaving the
panel defaulted to NO causes the panel to always send zone tripped messages in
addition to supervision, tamper, and low battery.
33.8.6
Wireless PIR Pulse Count
Select the number of infrared pulse counts (2 or 4) the PIR will use before sending
a short message. The first infrared pulse starts a timer and count. If no additional
infrared pulses occur in 25 seconds, the timer and count are reset. Default is 4.
33.8.7
Wireless PIR Sensitivity
Select the sensitivity setting for the PIR. Selecting LOW sets the PIR to operate at
75% sensitivity for installations in harsh environments. Selecting HIGH sets the PIR
to maximum sensitivity. Default is LOW.
33.8.8
Next Zone
Select YES to return to the ZONE NO: - option to program a new zone. Select NO to
display the Alarm Action option.
33.9 1144 Series Key Fobs
Only zones 51-54 or 61-64 can be programmed as 1144 Series Key Fob zones. Refer to the 1100 Series Key Fob
Programming Sheet (LT-0706) and the 1144 Series Key Fob Install Guide (LT-1449) as needed.
To operate arming and disarming properly, the Key Fob should be assigned to a User Number with appropriate
To operate arming and disarming properly, the Key Fob should be assigned to a User Number with appropriate
area assignments, however, the User Number does not have to exist at the time the Key Fob is programmed. The
User Number can be added at the User Menu later by the User.
The following programming continues from when Key Fob YES is selected.
The following programming continues from when Key Fob YES is selected.
33.9.1
Key Fob User Number
Enter the User Number used to identify the key fob user and their arming and
disarming authority. Default is blank.
— User number range: 1 to 99
Displays when the User Number entered does not exist in User Code programming.
The key fob can be added, but the user must eventually be added to cause the key
fob to operate.
33.9.2
Key Fob Serial Number
Enter the eight-digit serial number found on the wireless device.
Displays when the serial number is already programmed. The programmed zone
number displays.
33.9.3
Key Fob Supervision Time
Press any top row key to select the supervision time required for the key fob zone.
Press COMMAND to accept the default time. Default is 0.
Press the select key under the required number of minutes. The key fob must
Press the select key under the required number of minutes. The key fob must
check in at least once during this time or a missing condition is indicated for that
zone. 1144 Series key fobs automatically checkin based on the supervision time
selected for the wireless zone, no additional programming is needed. Zero (0)
indicates an unsupervised transmitter.
Note: When the panel is reset the supervision timer restarts for all wireless zones.
33.9.4
Number of Key Fob Buttons
Enter the number of buttons (1, 2, or 4) on the key fob being programmed. Default
is four buttons.
Note: If the key fob is a one-button model, programming continues at the Button
Note: If the key fob is a one-button model, programming continues at the Button
Action section. Default button assignment for one-button key fobs is a Panic Alarm
(PN) with no output assigned.
33.9.5
Key Fob Button Selection (Four Buttons)
This option only displays if the key fob being programmed is a four-button model.
DISARM DISABLE
NO YES
WIRELESS PIR
PULSE COUNT: 4
PULSE COUNT: 4
WIRELESS PIR
SENSITIVITY: LOW
SENSITIVITY: LOW
NEXT ZN NO
YES
KF USER NO:
NOT IN USE
SERIAL #: -
ALREADY USED
Zxx
SUPRVSN TIME:
0
0 60 240
BUTTONS: 4
TOP BTM LFT RGT