DESCRIPTION
1
PROGRAM THE PANEL
The 1158 can be programmed with up to eight zones. When 
programming the 1158 in the panel, refer to the panel 
programming guide as needed.
Program the serial number associated with contacts 1 
through 4 first. Then, be sure to start by programming 
contact 1.
When you enter the serial number associated with contacts 
5 through 8, contact 1 displays again indicating that you are 
programming the first contact associated with that serial 
number.
1.  In 
ZONE INFORMATION, enter the ZONE number, and 
then press 
CMD.
2.  Enter the 
ZONE NAME and press CMD.
3.  Once 
ZONE TYPE appears, select the appropriate 
zone type, and then press 
CMD.
4.  At the 
NEXT ZONE prompt, select NO. If you see the 
WIRELESS ZONE prompt, select YES.
Note: If you are programming the 1158 onto a 
zone that can be either hard wired or wireless, 
then this prompt appears. If the zone you are 
programming is wireless-only, then the prompt 
does not appear.
5.  Enter the eight-digit 
SERIAL NUMBER and press CMD.
6.  Enter the 
CONTACT number being used. 
7.  Enter the 
SUPERVSN TIME and press CMD.
8.  At the 
NEXT ZONE prompt, select YES and continue 
to program up to seven more zones.
Note: Zones must be entered sequentially. For 
example, if you begin by programming zone 71, 
you would need to program zone 72 as the next 
contact.
Supervisory Message
When a wireless receiver is installed, a receiver is restarted, 
the panel is reset, or if programming is complete, then the 
supervision time is reset. 
If the receiver has been powered down for more than one 
hour, then the 1158 may take up to an additional hour to send 
a supervision message. 
A missing message may display on the keypad until the 
supervision message is sent.
Figure 1: 1158 Housing
When a DMP panel is installed in a 
location with an existing non-DMP 
panel, the 1158 Wireless Eight-Zone 
Takeover Module can be used to 
convert up to eight existing normally 
closed, hardwired zones into wireless 
zones. This allows the new DMP 
panel to communicate with existing 
zones.
The 1158 uses two serial numbers to 
accommodate up to eight zones and 
can be powered by transferring AC 
and battery power from the existing 
panel. 
Compatibility
All DMP 1100 Series Wireless 
Receivers and burglary 
panels. See the last page for 
compatibility details.
What is Included?
•  1158 Wireless Eight-Zone 
Takeover Module
•  Hardware pack
1158 WIRELESS EIGHT-ZONE 
TAKEOVER MODULE
Installation Guide