800-24121  5/18  Rev. A  Part 1 (BETA) 
 
ADT7AIO/ADT5AIO Series Installation and Setup Guide 
 
 
STEP 1 -  Installing the Rechargeable Backup Battery and 
Power Connector 
The control is designed to be placed on a desk/table top with the stand attached or 
mounted to a wall using the back plate/cover.
 
1.
   
Remove the Control’s Case Back. 
2.  Install the ADTZWM (Wi-Fi
®
 and Z-Wave
®
) and/or ADTLTE Communications 
modules (if used). 
2.    Connect the battery connector to the receptacle on the PC board. 
3.   Insert the Battery Pack into the case. 
4.    Secure the Battery Pack with the Battery Retainer using the Retaining Screw. 
5a.  Connect the power cable to the GND and +9V terminals on the AIO and to the + 
and – terminals on the Power Supply. Refer to Table 1 for wire gauge and length. 
Do not apply power at this time.  OR 
5b  Connect the power supply connector to the receptacle on the AIO. Do not apply 
power at this time.   
NOTE:   If using the optional wall mount configuration, skip to the wall mounting 
procedure. If not, complete step 7. 
6.    Install the Case Back onto the contorl and secure with the screw.  
 
Optional ADTZWM and ADTLTE Communications Module Note: Refer to the Specific 
Module Installation
 section in the online Installation & Reference Guide for instructions on 
mounting this module. 
 
ADTZWM
MODULE
ADTLTE
MODULE
COVER
SCREW
SCREW
BATTERY
g
ri
p
-0
0
9
-V0
SCREW
TERMINAL BLOCK
POWER
SUPPLY
RECEPTACLE
DETAIL A
BATTERY
CONNECTOR
EXT
INT
MACHINE
SCREW
GND
9V
 
 
Table 1 – Wiring Guide 
Maximum distance between 
power supply and control  
Wire Gauge 
(AWG) 
 Note:  Use UL-listed limited energy 
cable 
Up to 25 feet (7.62m) 
# 22 
Up to 45 feet (13.72m) 
# 20 
Up to 70 feet (21.34m) 
# 18 
Up to 110 feet (33.53m) 
# 16 
Mounting the Base to a Wall (Optional) 
 
For wall mounting, perform to the following: 
1.    Secure the Mounting Plate to the wall with 4 screws. 
2.    Install the Tamper Screw as shown.  
3.    Secure the Control to the Mounting Plate by aligning the slots on the Base and 
sliding the unit down until locked in position. 
4.  Secure the Control with the screw. 
 
 
STEP 2 - Setting up the Communication Links 
Note: Do not connect to a receptacle controlled by a switch. 
1.  Plug the power supply into a 24-hour, 110VAC unswitched outlet. Upon power-
up, the “Please Standby!” will be displayed on the home screen. 
2.  Connect the Control to the local router.  
 
STEP 3 - Registration Programming and Testing
 
On a laptop, PC or Smart Device, go to: https://alarmadmin.alarm.com. 
 
IMPORTANT: Once the programming procedure has started and the unit is 
powered up, do not remove power or disconnect the battery, nor open the case. 
Disconnecting power or activating the tamper switch can cause unpredictable 
programming results. 
 
Radio Activation  
Refer to the https://alarmadmin.alarm.com for radio activation. 
 
Testing the System 
The following test modes are available:  
• 
Walk Test 
• 
Communication Diagnostics  
 
Enter Test mode (Walk Test) 
1.  After entering Installer Tools Menu Mode, select the “Test” button. 
2.  Select “Walk Test”. The system enters Walk Test Mode and “Walk Test-Home To 
Quit” is displayed 
3.  Open each protected door and listen for three beeps from the keypad, followed 
by the zone’s Voice Descriptor. Identification of each faulted protection point 
should appear on the display, and clear when the door is closed. 
4.  Walk in front of the motion sensor and listen for three beeps and the zone’s voice 
descriptor.  
5.  When testing is complete, select the Home button and enter the Installer Code.  
6.  Press each key on the wireless key to confirm it performs its assigned function.
 
 
Specifications 
Dimensions:   
7.875” W x 5.75” H x 1.0” D 
Voltage Input: 
P/N 300-10260: White – 9VDC, 2.5A 
P/N 300-10260-BK (Black) – 9VDC, 2.5A 
P/N 300-10260-CAN (Canada) – 9VDC, 2.5A 
24-Hour Backup Battery: 
P/N 300-10186: Rechargeable Backup Battery: 
Lithium-ion battery pack rated at 3.6/4.2V, 7500 mAH 
Communication Formats: 
4-Digit Contact ID 
 
Home Health Care Applications 
IMPORTANT: In Home Health Care applications [UL1637] you must use pendant 
model SiXMEDICAL. The maximum range is 50 ft.  
 
Contacting Technical Support 
 
PLEASE, before you call Technical Support, be sure you: 
READ THE INSTRUCTIONS! 
•  Determine that the power supply and/or backup battery are supplying proper 
voltages. 
•  Verify your programming information where applicable. 
•  Note the proper model number of this product, and the version level (if known) 
along with any documentation that came with the product. 
•  Note your ADT customer number and/or company name. 
 
Having this information handy will make it easier for us to serve you quickly and 
effectively. 
 
For Documentation and Online Support 
See Installation and Setup Guide P/N 800-24121 or higher, which can be 
ordered by contacting Customer Service at 1-800-238-2727 (1-800-ADT-
ASAP). For technical support please call the ADT Product Support Group at 
1-877-748-7628, option 3
 
This  system  must  be  checked  by  a  qualified  technician  at  least  once 
every three (3) years