ademco 8DL6OCC Benutzerhandbuch
7
LED INDICATORS
GENERAL STATUS
PATTERN
TIME DURATION
OCCASION
No programmed network (Green LED)
100ms ON, 100ms OFF
8 seconds
Powered on, but never
connected to a network
connected to a network
Programmed into a network (Green
LED)
LED)
3s ON / 3s Off
Continuously?
Power on, connected to a
network (even if already
enrolled into another
network)
network (even if already
enrolled into another
network)
Selection (Red LED)
ON selected; OFF when cancel
The time of selection
When the user select’s it,
command from 5168
command from 5168
Warm Up (Red LED)
1s on, 1s Off
6-45 seconds
Power on or Reset
RED LED
Enter/Exit walk test mode
20ms ON, 20ms OFF
2 seconds
Enter or Exit Walk Test
mode
mode
Trouble /
Tamper
200ms ON, 4800ms OFF
Flash if the error exists
Any trouble condition?
Alarm no Pet Immunity / Panel
programmable
programmable
100ms ON, 100ms OFF
3 seconds
Alarm in walk test mode
Alarm with Pet Immunity / Panel
programmable
programmable
3s ON, 3s OFF
3 seconds
Alarm in walk test mode
GREEN LED (INTRUSION)
Off
N/A
N/A
Normal operation when no
activity detected
activity detected
Delete
100ms ON, 100ms OFF
2 seconds
During enrolment
Tamper/
Trouble
200ms ON, 1800ms OFF
10 minutes
Tamper triggered or
Any
trouble condition?
GREEN LED (OCCUPANCY)
Occupancy Alarm
3s ON
3 seconds
Alarm in walk test mode
GREEN LED DURING THE ENROLLMENT
3s ON
/ 3s OFF
3 seconds
Process is complete and
enrollment confirmed
enrollment confirmed
REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL WITH WHICH THIS DEVICE IS USED, FOR DETAILS
REGARDING LIMITATIONS OF THE ENTIRE ALARM SYSTEM.
REGARDING LIMITATIONS OF THE ENTIRE ALARM SYSTEM.