SiXPANIC
 
2-Button Wireless Panic Key 
Installation Instructions 
 
This bi-directional wireless panic key is intended 
for use with Honeywell controls that support 
SiX™ series devices.  
To activate, press and hold both buttons briefly 
until the LED flashes. To clear the alarm at the 
control, enter a user code. To clear memory of 
alarm, select Disarm and enter a user code. 
 
 
 
The device can be used with a belt clip, lanyard, 
or wristband.
 
[images of belt clip, wristband, necklace] 
LED Indications 
Green flashing: lights when unit is transmitting 
Red Flashing:   indicates low battery (lights 
during key press) 
 
Enroll and Program the SiXPANIC  
For the Lyric™ Controller 
Follow instructions in the Controller’s programming guide.  
1.  Set the Lyric Controller in Programming Mode: 
Security > 
Tools > [installer code] > Program > (scroll down) > SiX 
Programming
2.  Press and hold both buttons briefly until the LED flashes to 
activate the enrollment process. 
3.  The LED flashes green during enrollment (up to about 20 
seconds). 
NOTE: Enrollment time varies depending on the signal 
strength between the device and the controller. 
  The device sends its unique MAC ID (Serial Number) and 
Services information to the controller.   
  The controller registers the device and displays the 
transmitter data on screen. 
4.  When done, the LED lights solid green for 3 seconds to 
confirm enrollment.   
If enrollment is not confirmed, press and hold both buttons 
briefly again to restart the enrollment process. 
5.  Press 
Edit to set the Alarm Report option on/off (if selected, 
button press sends a report to the central station). Press 
Save. Enter an appropriate Zone Descriptor. Press Save
 
The device can also be manually enrolled.  See the Controller’s 
Programming Guide for details. 
For the Lyric™ Gateway 
Enroll and program using AlarmNet 360™. 
For other Controls 
For other Controls that support SiX Series devices, see the 
controller’s instructions for enrollment details. 
 
 
IMPORTANT: Once enrolled in a system, the SiXPANIC cannot 
be used with another controller until it is removed from the 
current controller.  When removed from a system, the key fob will 
revert to factory default settings. 
Sensor Location Feature: To verify the location of each SiX 
device in an installation, enter programming mode and select a 
SiX device. The device LED lights. Select it again to turn the LED 
off, or select the next device to locate. 
After Enrolling: Verify adequate signal strength by conducting 
Go/No Go tests (see controller’s instructions) with the device in 
its intended mounting location. Adjust the device location as 
necessary. 
24-Hour Enrollment Deletion and Default 
If the device is enrolled in a panel different than the intended 
panel, and you are unable to delete it from the unintended panel, 
reset the device to factory default setting: 
Press and hold the left button for 15 seconds. 
The device self-deletes from the panel it was enrolled in. 
This procedure is available for 24 hours after enrollment with a 
panel and the device remains powered (battery installed).
 
 
 
 
 
Press and hold the left button 15 seconds.