UltraLine IIB (Model A90-816030)
Connection
Edit Connection
Factory Default = MainPPP
The name of the default connection profile. Westell recommends that you use the
Default parameter.
The name of the default connection profile. Westell recommends that you use the
Default parameter.
Connection Name
This field allows you to enter a new connection name of your choice (up to 64
characters).
characters).
Account ID
The account ID (provided by your Internet service provider ).
Account Password
The account password that you are using to connect to your Internet service provider
(provided by your Internet service provider ).
(provided by your Internet service provider ).
Connection
Factory default = Always On
Manual: Selecting this feature allows you to manually establish your PPP session.
On Demand: Selecting this feature allows the Gateway to automatically re-establish
your PPP session on demand anytime your PC requests Internet activity (for example,
browsing the Internet, email, etc.). When you have traffic, it may cause a delay.
Always On: Selecting this feature allows the Gateway to automatically establish a PPP
session when you log on or if the PPP session goes down.
Manual: Selecting this feature allows you to manually establish your PPP session.
On Demand: Selecting this feature allows the Gateway to automatically re-establish
your PPP session on demand anytime your PC requests Internet activity (for example,
browsing the Internet, email, etc.). When you have traffic, it may cause a delay.
Always On: Selecting this feature allows the Gateway to automatically establish a PPP
session when you log on or if the PPP session goes down.
MRU Negotiation
Factory Default = Enabled
When Enabled is selected, the Maximum Received Unit (MRU) will enforce MRU
negotiations.
If Disabled, this function will not be activated.
When Enabled is selected, the Maximum Received Unit (MRU) will enforce MRU
negotiations.
If Disabled, this function will not be activated.
LCP Echo
Factory Default = Enable
If Disabled is selected, this option will disable the modem LCP Echo transmissions.
If Disabled is selected, this option will disable the modem LCP Echo transmissions.
LCP Echo Failures
Factory Default = 6
Indicates number of continuous LCP echo non-responses received before the PPP
session is terminated. This value must be between 1 and 30 inclusive.
Indicates number of continuous LCP echo non-responses received before the PPP
session is terminated. This value must be between 1 and 30 inclusive.
LCP Echo Duration
Factory Default = 30
The interval between LCP Echo transmissions with responses. This value must be
between 5 and 300 seconds inclusive and greater than or equal to the Retry Duration.
The interval between LCP Echo transmissions with responses. This value must be
between 5 and 300 seconds inclusive and greater than or equal to the Retry Duration.
LCP Echo Retry Duration
Factory Default = 5
The interval between LCP. Echo after no response.
This value must be between 5 and 300 seconds inclusive.
The interval between LCP. Echo after no response.
This value must be between 5 and 300 seconds inclusive.