Axcera 79XITS-7045 Benutzerhandbuch

Seite von 56
WaveCom Electronics Inc
MA4040D Manual; MAN1L0901 REV 13(0104)
Approved: D.P.
27
6.0 ERROR CODES
6.1 MA4040D Error Codes
When the error code is non-zero, it is displayed on line 2 of the LCD display. It consists of an ‘e’ character followed
by a 2 digit hexadecimal number. The following table can be used to interpret the meaning of the digits.
TT
A B L E  
A B L E  
6.1
6.1
A
A
: M
: M
O S T  
O S T  
SS
I G N I F I C A N T  
I G N I F I C A N T  
D
D
I G I T  
I G I T  
D
D
E S C R I P T I O N
E S C R I P T I O N
Digit
Description
0
None
1
Fixed LO Error
2
IF AGC Error
3
IF AGC Error, Fixed LO Error
4
IF Threshold Error
5
IF Threshold Error, Fixed LO Error
6
IF Threshold Error, IF AGC Error
7
IF Threshold Error, Fixed LO Error
8
RF Threshold Error
9
RF Threshold Error, Fixed LO Error
A
RF Threshold Error, IF AGC Error
B
RF Threshold Error, IF AGC Error, Fixed LO Error
C
RF Threshold Error, IF Threshold Error
D
RF Threshold Error, IF Threshold Error, Fixed LO Error
E
RF Threshold Error, IF Threshold Error, IF AGC Error
F
RF Threshold Error, IF Threshold Error, IF AGC Error, Fixed LO Error
TT
A B L E  
A B L E  
6.1
6.1
BB
:   L
:   L
E A S T  
E A S T  
SS
I G N I F I C A N T  
I G N I F I C A N T  
D
D
I G I T  
I G I T  
D
D
E S C R I P T I O N
E S C R I P T I O N
Digit
Description
0
None
1
Output is Muted
2
Hard Alarm condition
3
Hard Alarm condition, Output is Muted
4
Soft Alarm condition
5
Soft Alarm condition, Output is Muted
6
Soft Alarm condition, Hard Alarm condition
7
Soft Alarm condition, Hard Alarm condition, Output is Muted
8
Variable LO Error
9
Variable LO Error, Output is Muted
A
Variable LO Error, Hard Alarm condition
B
Variable LO error, Hard Alarm condition, Output is Muted
C
Variable LO Error, Soft Alarm condition
D
Variable LO Error, Soft Alarm condition, Output is Muted
E
Variable LO Error, Soft Alarm condition, Hard Alarm condition
F
Variable LO Error, Soft Alarm condition, Hard Alarm condition, Output is Muted