Axcera 79XITS-7045 Benutzerhandbuch

Seite von 56
WaveCom Electronics Inc
MA4040D Manual; MAN1L0901 REV 13(0104)
Approved: D.P.
30
CC = Command Code (2 or 3 ASCII characters)
FL = Load Frequency
IAS = Set IF AGC Threshold
RTE = Enable RF Threshold
AI = Set IF Attenuation
IAE = Enable IF AGC Threshold
RTD = Disable RF Threshold
AR = Set RF Attenuation
IAD = Disable IF AGC Threshold
SU = Unit Status Request
OE = Enable Output
ITS = Set IF Threshold
SC = Configuration Status Request
OD = Disable Output
ITE = Enable IF Threshold
LE = Enable Local Control
BE = Backup Relay Enable
ITD = Disable IF Threshold
LD = Disable Local Control
BD = Backup Relay Disable
RTS = Set RF Threshold
CRC = CRC-16 checksum (3 characters)
The checksum is preferred, but not required. If the checksum is used, the first character is an ASCII “V” followed
by the low and high bytes respectively of the computed CRC 16 checksum (the checksum characters are not
necessarily ASCII). The checksum is to be computed on all characters after the initial <start> character up to,
and including, the first “V” character in the CRC section. If the checksum is not used, the 3 characters should be
ASCII “NNN” (they must be uppercase).
PARM is one or more characters, and is command specific.
*
The command syntax for Terminal Mode is the same as above with the following modifications:
1) Commands should not have an initial asterisk
2) The CRC is ignored
3) The maximum length is 49 characters
4) All commands are parsed from left to right.  Only the first command on a line is
processed, any additional characters are ignored.