MA4040D Manual; MAN1L0901 REV 13(0104)
Approved: D.P.
34
OD - Disable Output
Description: Turns off the Output from the specified module.
Parameters: None
Example:
*999<sp>A<sp>OD<sp>CRC<cr>
Response: OK or MOD or ERR or CRC
BE - Backup Relay Enable
Description: Enables the backup relay on the specified module. This allows the IF input to the card to be switched to
a redundant card in the event of module failure.
Parameters: None
Example:
*999<sp>A<sp>BE<sp>CRC<cr>
Response: OK or MOD or ERR or CRC
BD - Backup Relay Disable
Description: Disables the backup relay on the specified module. This returns the card to normal functioning.
Parameters: None
Example:
*999<sp>A<sp>BD<sp>CRC<cr>
Response: OK or MOD or ERR or CRC
LE - Enable Local Control
Description: Enables local control of the MA4002D chassis. The module address must indicate a valid module even
though the command does not change any module settings.
Parameters: None
Example:
*999<sp>A<sp>LE<sp>CRC<cr>
Response: OK or MOD or ERR or CRC
LD - Disable Local Control
Description: Disables local control of the MA4002D chassis. The module address must indicate a valid module even
though the command does not change any module settings.
Parameters: None
Example:
*999<sp>A<sp>LD<sp>CRC<cr>
Response: OK or MOD or ERR or CRC