Williams Sound DLT300 Benutzerhandbuch

Seite von 33
DLT 300 3.0 Digital Transceiver and DLR 360 3.0 Digital Receiver
28
Troubleshooting
PROBLEM
CAuSE
WHAT TO DO
Power does not turn-on
Dead battery
Charge the battery, replace battery
Power turned off 
automatically
Master device can’t be found
Turn on Master unit
Power doesn’t turn off
Program Error
Press reset button on the back of device (DLT only)
No audio in headphones
Disconnection of headphone
Check headphone connection
Master unit shut off
Turn on / set master
Different Group Number settings
Set every unit to the same group number
Out of range
Move to within the range of 100ft (outside) or 200 ft 
(inside) from the master unit
More than 1 master exists in a group
Set one master per group
Obstacle exists
Move to another place or move the obstacles
More than 2 units with same address exist in a group
Set different address
Error in attendee 
checking
More than 2 units with same address exist in a group
Set different address
unable to select receiving 
channel
Transmitting channel is overlapping
Set different transmitting channel
unable to transmit 
Interpretation
Please check the mode for simultaneous interpretation 
mode
Set simultaneous interpretation mode
More than 2 master units exist
Set one master only
DLT keeps turning off
Master unit shut off
Turn on / set master
Can’t hear the speaker
Mic Sensitivity too low
See first, which microphone you have, and then adjust 
the sensitivity accordingly.  (i.e., Mic 044-2p is about 
33, Mic 068 is about 17).
Master unit shut off
See why the Master shut off and correct the problem.  
Turn on the Master and verify the battery level.
The microphone and 
headphone will not work
Microphone and Headphone connections are 
reversed
Verify first, then swap the connections.
The TALK button is 
flashing
The talk button has been held down too long and the 
system is now in “Talk Mute” mode.
Hold down the talk button until the talk button stops 
flashing.  This will disable talk mute.
A DLT will not sync to 
Master 1
Out of Range
Bring the unit closer to the master
Master is Off
Turn Master unit on
No 4-digit Secure Code, or Incorrect Code
Make the secure code the same as the master
Wrong Group Number
Make group numbers match the master
Group number above 100 (DLR)
Change all units to a group number under 100
“GST” is blinking
The Guest has not found a Master to sync to.
Program at least one unit as the Master or turn on the 
existing Master.  Verify that the Group numbers match.
Time of Day Incorrect
Time of Day on Master 1 is Incorrect.  (All units sync 
their time from Master 1)
Set time of day to the correct time on Master 1.