Sebury Technology Co. Ltd. W3-H Benutzerhandbuch

Seite von 2
User  Manual
.8.
.10.
D0
D0
D1
D1
ALARM-
OPEN
D_IN
 DC
/3A
12V
W3-H
Door detecting switch
-
-
+
+
-
+
Special Power Supply
Alarm
GND
AC&DC
AC&DC
NC
COM
NO
NC
COM NO +12V GND
V+
GND
OPEN
Green
White
Grey
Yellow
Brown
Red
Black
Blue
Purple
Orange
Pink
Exit button
Wiegand reader
Fail-Secure lock
Fail-Secure lock
Figure 2
Transmission Format:
1: Keypad Transmission 
The Reader will transmit the PIN data when it receives the last key (#) press after PIN 
code.
Format:  PIN Code ( any 4-8 digits between 0000-99999999)
Example: PIN code:111111
Press 111111 #, then the output format will be: 0000111111
(
l
   
2: Proximity Card Transmission 
The Reader will transmit the card data when it reads the Card.
Format: Card Number
(Note: No matter the card is valid or invalid, the data will be transmitted)
l
   
Note: if press an invalid PIN (any 4-8 digits), the data will be also transmitted.)
14.2  W3-H operating as a Controller
In  this  mode  the  W3-H  supports  a  Wiegand  26-37  bit  input  so  an  external  Wiegand 
device with a 26-37 bit output can be connected to the Wiegand input terminals on the 
W3-H.  Either  an  ID  card  reader  (125KHz)  or  an  IC  card  reader  (13.56MHz)  can  be 
connected to the W3-H. Cards are required to be added at the external reader, except 
where an external HID reader is used, in this case cards can be added at either reader 
or controller. See figure 2.
D0
D1
ALARM-
OPEN
D_IN
W3-H
GND
AC&DC
AC&DC
NC
COM
NO
Controller
V+
V+
GND
GND
D0
D1
Power
Green
White
Grey
Yellow
Brown
Red
Black
Blue
Purple
Orange
Pink
Figure 1
W3-H Quick Reference Programming Guide
To enter the programming mode
*  Master code   #
888888 is the default factory master code 
To exit from the programming mode
*
Note that to undertake the following programming the master user must be logged in
To change the master code
0    New code    #   New code   #
The master code can be 6 digits long
1    User ID number    #    PIN    # 
The ID number is any number between 
1-2,000. The PIN is any 4-8 digits between 
0000 - 99999999 with the exception of 1234 
which is reserved. Users can be added 
continuously without exiting programming 
mode
To add a PIN user
1   Read Card    #
Cards can be added continuously without 
exiting from programming mode
To add a Card user
To delete a PIN or a Card user
2    User ID number   #  for a PIN user or
2    Read Card   #  for a card user
To unlock the door
To unlock the door for a PIN user
To unlock the door for a card user
Enter the  PIN  then press   #
Present the card 
.7.
To change a PIN in card and PIN 
mode (Method 1) 
Note that this is done outside 
programming mode
 
so the user can 
undertake this themselves
To change a PIN in card and PIN 
mode (Method 2) 
Note that this is done out
 
programming mode
 
so the user can 
undertake this themselves
side 
To delete a Card and PIN user just 
delete the card 
*  Read Card  Old PIN #   New PIN #   New PIN #
*   ID number #  Old PIN #   New PIN #  
New PIN #
2  User ID   #
.9.
To set keypad tone
 7   8   #   To disable the keypad tone
 
 
 
 7   9   #   To enable the keypad tone(Factory default) 
To set LED
 7   6   #   To disable the red LED
 
 
 
 
 7   7   #   
 
To enable the red LED(Factory default) 
13. Wiegand Mode Setting
W3-H supports Wiegand 26-37, both input and output. It can be used as a reader or controller.
To set Wiegand format:
9  26-37  #   (Default setting: Wiegand 26)
14. 
Interconnecting Two Devices
14.1 W3-H operating as a Wiegand Output Reader
In this mode the W3-H supports a Wiegand 26-37 bit output so the Wiegand data lines 
can be connected to any controller which supports a Wiegand 26-37 bit input. 
See figure 1.
To set Duress PIN user
12. Duress User Settings
There are 10 groups Duress PIN/card available. When input Duress PIN/card, the door
 will open, at the same time, the output alarm operates.
To add a PIN user
To delete a PIN user
To set Dur ss card user
e
To add a card user
To delete a card user
(The ID number is any number between 2001 2010)
-
Note: 
① User ID number must be any 4digits between 2001 2010
② Duress PIN/card must be unique, should be distinguished from common PIN and card
(When the Duress PIN/card is the same with common PIN and card, they will become invalid 
in Duress, and worked as common user function)
-
(The ID number is any number between 2001-2010)
To remove the alarm
To reset the Door Forced Open warning
 Read Valid Card or Master Code #
To reset the Door Open Too Long warning
Close the door or  Read Valid Card or  Master Code #
W3-H
 Waterproof 
Keypad/Reader/Controller
1. Packing list
Name
Digital Keypad W3-H
Quantity
Remark
Screw Driver
Rubber  Bungs
Self Tapping Screws
Diode
1
    4
4
1
6*27mm, used for fixing
4*28mm, used for fixing
IN4004
User Manual
1
1
Please ensure that all the above contents are correct. If any are missing please notify 
the supplier of the W3-H. 
.1.
Manager Card
2
Manager Add Card & Manager Delete Card
The W3-H is a single door multifunction access control with HID card reader. It is 
suitable for mounting either indoor or outdoor in harsh environments. It is housed in a 
strong, sturdy and vandal proof zinc alloy electroplated case. The electronics are fully 
potted so the W3-H is waterproof and conforms to IP68. 
The W3-H supports up to 2,000 users in either a Card, 4-8 digits PIN, or a Card + PIN 
option and additional 10 groups Duress PIN/Card. The built-in card reader supports HID 
125KHz frequency cards/tags. The W3-H has many extra features including Duress 
PIN/card, block enrollment, Wiegand 26-37 bits interface, and backlight keypad…etc. 
These features make W3-H an ideal choice for door access not only for small shops and 
domestic households but also for commercial and industrial applications such as 
factories, warehouses, laboratories, banks and prisons.
2. Description 
Waterproof, conforms to IP 68 
Strong zinc alloy electroplated anti-vandal case
Full programming from the keypad
2,000 users, supports Card, PIN, Card + PIN 
10 groups Duress PIN/Card
Card interface: HID 125KHz Card
Can be used as a standalone keypad, PIN length 4-8 digits
Pulse mode, Toggle mode
l
   
l
   
l
   
l
   
l
   
l
   
l
   
l
   
3. Features
.2.
PCB connect diagram
Anti-demolition alarm
D
0
D
1
A
L
A
R
M
-
O
P
E
N
D
_
IN
G
N
D
A
C
&
D
C
A
C
&
D
C
N
C
C
O
M
N
O
J1
D
0
D
1
A
L
A
R
M
-
O
P
E
N
D
_
IN
G
N
D
A
C
&
D
C
A
C
&
D
C
N
C
C
O
M
N
O
J1
W3-H
5. Installation
l
 
l
 
l
 
l
 
l
 
Remove the back cover from the keypad using the supplied security screwdriver
Drill 4 holes on the wall for the screws and 1 hole for the cable
Fix the back cover firmly on the wall with 4 flat head screws
Thread the cable through the cable hole
Attach the keypad to the back cover
.3.
4. Specifications
Operating Voltage
12-24V DC or 1 -18V AC
2
2,000  (Additional10 groups Duress PIN/Card)
Adjustable Door Relay Time
Adjustable Alarm Time
Wiegand Interface
Wiring Connections
Wiegand 26-37 input & output
L128 X W82 X H28mm
600 g
700 g
12 keys: 3 X 4 digits
Operating Humidity 
Dimensions
Net Weight 
Gross Weight
10%-90% RH
1-99 seconds
Electric Lock,  Exit Button, 
 
DOTL, External Alarm
Operating Temperature
-20-50
HID 125KHz card
3-6 cm
Max 2A
Max 20A
User Capacity
Keypad
Card Type
Card Reading Distance
Lock Output Load
 
Alarm Output Load
Active Current
Idle Current
≥65mA
≥35mA
Environment
Conforms to IP68
0-3 minutes
6. Wiring
Colour
Grey
Yellow
Brown
Red
Black
Blue
Purple
Function
D0
Alarm -
OPEN
D-IN
 12-24V DC or 12-18V AC 
NO
COM
Description
Wiegand Output D0
White
Wiegand Output D1 
Request to Exit Button
Door Contact
 12-24V DC or 12-18V AC Regulated Power Input
 12-24V DC or 12-18V AC Regulated Power Input
Alarm Negative 
Orange
NC
Pink
GND
Green
D1
Relay NO 
Relay COM
Relay NC
W3-H Negative
 12-24V DC or 12-18V AC 
.4.
The relay on board can operate in Pulse Mode (suitable for access control) or Toggle 
Mode (suitable for arming/disarming alarms, switching lights, machines….etc) 
Every time a valid tag/card or PIN is read/input in Pulse Mode, the relay will operate, for 
the pre-set relay pulse time.
Every time a valid tag/card or PIN is read/input in Toggle Mode, the relay changes state, 
which will not turn back until read card or input PIN again.
8. Relay operation (Pulse mode and Toggle mode)
9.  To Reset to Factory Default
To reset to factory default, power off, press     , hold it and power on, release it until hear 
two beeps and the LED shines in orange, then read any two HID cards, the LED will turn 
in red, means reset to factory default setting successfully. Of the two HID cards read, the 
first one is Manager Add Card, the second one is Manager Delete Card.
Remarks: Reset to factory default, the user's information is still retained. 
*
7. Anti Tamper Alarm
The W3-H uses a LDR (light dependent resistor) as an anti tamper alarm. If the keypad 
is removed from the cover then the tamper alarm will operate. 
.5.
.6.
10. Sound and Light Indication
Operation Status
Power on
Operation successful
Operation failed
Enter into programming mode
Red Light
-
-
-
Bright
Bright
Bright
Green Light
-
-
Bright
-
-
-
Buzzer
Short Ring
-
Short Ring
Short Ring
3 Short Ring
Short Ring
-
Short Ring
Press keypad
-
-
Stand by
In the programming mode
Exit from the programming mode
Open the door
Bright
-
Bright
Alarm
-
Alarm
Bright
-
Short Ring
Yellow Light
-
-
-
-
-
Bright
-
-
-
-
11. W3-H Detailed Programming Guide 
11.1 User Settings
To exit from the programming mode
To change the master code
set valid card only users
set valid card and PIN users
set valid card or PIN users
*     Master code     # 
888888 is the default factory master code
To enter the programming mode
*     
Note that to undertake the following programming the master user must be logged in
0   New code    #   New code    #
The master code is any 6 digits
Setting the working mode:
3 0
#
3 1
#
3 2
#
Entry by either Card or PIN (default)
Entry by Card only
Entry by Card and PIN together
To set a user in either card or PIN mode   (  3   2   #  )    (Default setting)
To add a PIN user
 1  User ID number   #   PIN   # 
The ID number is any number between 1- 
2000. The PIN is any 4-8 digits between 0000 
-99999999 with the exception of 1234 which 
is reserved. Users can be added
 
continuously 
without exiting from
 
programming
 
mode
 
as
 
follows:
 1   User ID No 1   #   PIN   #  User ID No 2   #   PIN   #
To delete a PIN user
 2  User ID number  #  
Users  can  be  deleted  continuously  without 
exiting programming mode
To delete card user by card 
Note users can be deleted 
continuously without exiting 
from programming mode
2   Read Card    #  
To delete a card user by user ID
 
This option can be used when
 
a
 
user has lost their
 
card
2   User ID   #  
To add a card user (Method 3)
Add a series cards users - Block
Enrollment
5  ID number   #  The 1st Card number   # 
Card quantity   # 
Note that cards must be consecutive, and card
quantity is between 1-2000
Maximum 2,000 cards can be enrolled at a 
stretch within 2 minutes
To delete   card user by card number 
Users can be deleted 
continuously without exiting 
from programming mode
a
2   Card number   #  
To set a card and PIN user in card and PIN mode (   3   1   #   )
To Add a card and PIN user
(The PIN is any 4-8 digits between 
0000 - 99999999 with the 
exception of 1234 which is 
reserved)
Add the card as for a card user 
Press     to exit from the
 
programming mode
Then allocate the card a PIN as
 
follows:
    Read Card    1234 #   PIN #   PIN #
*  
*
To change the PIN of a PIN user 
(This step must be done out of 
programming mode)
To add a card user (Method 1)
This is a fastest way to add cards
 using ID number auto generation
To add a card user (Method 2)
T h i s i s t h e o p t i o n a l w a y t o a d d 
cards using User ID Allocation. 
In this method a User ID is allocated
to a card. Only one user ID can be
allocated to a single card
       ID number #    Old PIN #    New PIN #   
  New PIN #
*
1    ID number   #   Card   #
1   Read Card    #  
Cards can be added continuously without exiting 
programming mode
l
   
l
   
l
   
l
   
Wiegand 26-37 input & output
One programmable relay output, NO, NC, COM
Adjustable door output time, alarm time, door open time 
Card block enrollment
l
   
l
   
l
   
l
   
l
   
l
   
l
   
With Manager Cards for adding or deleting card user easily
Backlight keypad
Built in light dependent resistor (LDR) for anti tamper
Built in buzzer
Red, Yellow and Green LED display the working status
12-24V DC or 12-18V AC
Two-year warranty
W3-H
D0
D1
ALARM-
OPEN
D_IN
 DC
/3A
12V
-
+
Wiegand D0
Wiegand D1
GND
AC&DC
AC&DC
NC
COM
NO
NC
COM
NO
+12V GND OPEN
Green
White
Grey
Yellow
Brown
Red
Black
Blue
Purple
Orange
Pink
Door 
detecting switch
Exit button
Alarm
Power
+
-
+
-
Fail-secure lock
Alarm“-”
Special Power Supply
Connection Giagram
To add Card User by Manager Add 
Card
To set card users by Manager card
To delete Card User by Manager 
Delete Card
Manager add card  Read User card 
Manager add card  
Cards can be added continuously
Manager delete card  Read User Card  
Manager delete card
Cards can be deleted continuously
For a PIN user
Enter the PIN  then press #
For a card user
Read card
For a card and PIN user
Read card then enter PIN #
To unlock the door
To Add and Delete a card user
To delete All users
To delete ALL users 
Note that this is a dangerous option
so use with care
The operating is the same as adding and deleting 
a card user in 3   2   #
2   0000   #
To set a card user in card mode         (  3    0   #   )
Common Power Supply
D0
D1
ALARM-
OPEN
D_IN
Exit button
W3-H
-
+
Green
White
Grey
Yellow
Brown
Red
Black
Blue
Purple
Orange
Power
Alarm
GND
AC&DC
AC&DC
NC
COM
NO
Pink
-
+
Lock
In
4
0
0
4
Power“+”
Electric bolt:
NC
Electric strike:
NO
Power“+”
Alarm  -
“ ”
Door 
detecting switch
12-24V
 DC or 
12-18V
 AC/3A
Notes:
Connect the negative pole of the lock to NC is for Fail safe lock.
Connect the negative pole of the lock to NO is for Fail-secure lock. 
Keypad Lockout
Alarm Output
Normal status: No keypad lockout
or alarm
 7   0   #  
 
(Factory default)
 7   1   # 
 7   2   # 
Keypad  Lockout  &  Alarm  Output  options.  If  there  are  10  invalid  cards  or  10 
incorrect  PIN  numbers  in  a  10  minute  period  either  the  keypad  will  lockout  for  10 
minutes  or  the  alarm  will  operate  for  10  minutes,  depending  on  the  option  selected 
below.
Light and Sound Setting
To set the alarm output time (0-3 
minutes). Factory default is 1 minute
Alarm output time
9   0-3   #
To disable door open detection
Door Open Detection 
Door Open Too Long (DOTL) warning. When used with an optional magnetic contact 
or built-in magnetic contact of the lock, if the door is opened normally, but not closed 
after 1 minute, the inside buzzer will beep automatically to remind people to close the 
door and continue for 1 minute before switching off automatically.
Door Forced Open warning. When used with an optional magnetic contact or built-in 
magnetic contact of the lock, if the door is open by 
, or if the door is opened after 
20 seconds of the electro-mechanical lock not closed properly, the inside buzzer and 
alarm output will both operate. The Alarm Output time is adjustable between 0-3 
minutes with the default being 1 minute.
 
force
To enable door open detection
 6   1   # 
11.3  
Alarm, Sound and Light Settings
Door Detection, 
To set keypad backlight
 7   4   #   
 7   5   #   
To enable keypad backlight(Factory default) 
Toggle mode
Toggle mode
4   0   #
Pulse mode
(Door relay time setting)
Pulse mode(Factory default)
11.2  Relay Setting (Pulse mode,Toggle mode)
4   1-99   #
The door relay time is between 1-99 seconds,
the factory default setting is 5 seconds.
 6   0   #   (Factory default )
To disable keypad backlight