Description: XC-1XT provides unsurpassed wide area unsecured outdoor instruion detection.
Combining Microwave & PIR detection technologies the XC-1XT ensures excellent coverage without
nuisance alarms. Dual outputs allow the use of a single detector for annunciation and security,
or allow multiple functioning via different control device assignments.
 Outdoor Dual Technology Intrusion Detector
            
 40FT L X 56 W (12m x 17m)
For best results install the XC-1XT at a mounting height between 6.6 ft.(2.0m) and 8.2 ft. (2.5m).  Mount the unit so it is
looking into an area free of obstructions, do not mount the unit so it is looking directly at heating or cooling sources.  Avoid
viewing operating machinery or  objects which have the potential for movement.   Do not aim unit so it  is looking at public
road  /  pathways.
Installation:
Function Select Switch
Prior to re-attaching front cover to unit; Set PIR sensitivity, PulseCount, LED Enable, Detection mode, and 50/60Hz
Flourescent  Light  immunity  setting  (Selectable  Switch  1,2,3,4,5,  and  6)  as  desired.
If the detector is viewing a narrow  area, a PC setting of 4 should be avoided, as the small area may not allow enough
movement to detect intruders. A PC of “4” is best suited for a wide open detection area.  For High Security applications set
PIR Sensitivity to “High Sensitivity” =(SW1 & 2 = 120% or 100%), this allows for a quicker detection at the edge of the
detection  area.     Animal  Immunity  characteristics  are  not  available  when  a  “High  Sensitivity”  setting  is  configured  on  the
XC-1XT.      Animal  Immunity  function  is  enabled by  placing  PIR  Sensitivity  at  60%. Use  Microwave  Sensitivity  adjustment
potentiometer to  adjust Microwave  sensitivity (Preset  @ 50%).    A properly  adjusted MW  will detect  crossing movement  just
inside the  protected area but  not outside  of the PIR  coverage area.
SW-5 allow for the selection of Dual-Technology (MW & PIR) or PIR only detection modes.   A PIR only detection mode is
useful  when  there  is  operating  machinery  or  exposed  fans  always  active  within  the  protected  area.
If  the  installation  site  is  subject  to  severe  vibrations  (via  close  proximity  to  railroad  tracks  and  /or  large  truck  movement),
ensure that the mounting point is on a riged surface.  In some situations it may be necessary to place a piece of plywood
between the mounting surface and the  XC-1XT detector to buffer wall movement.
Walk-Test:
Once  installation and  initial  setup  is complete,  perform  a full  walk  test  to insure  that   the  detection  parameters  are met,  if
required  make control  adjustments  to fine  tune  detection characteristics.   In  order  to insure  detection  quality, the  XC-1XT
should be  tested routinely, with  no more than a  one year period  between tests.
Control Layout and Configuration:
Terminal Configuration
                    T     T     NC  NO   C    NC  NO    C                    
+      -
                             TAMPER             ALARM 1                  ALARM 2               SPARE          POW ER
LED  Indicators
Green = PIR
Red = Alarm
Amber = MW
Switch ON
Wire the XC-1XT to the control panel device using 18 to 24 AWG standard non-shielded wire, do not run wiring parallel to
AC wiring. Wiring should be in accordance with NEC, NFPA 70 for North America.
SW-1 &  2 :PIR  Sensitivity
Switch OFF
SW-1
SW-2
SW-6
SW-5
SW-3
SW-4
SW-3  Pulse  Count
3 off - PC2
3 on - PC4
SW-4  LED  Enable
4 off - LED’s Enabled
4 on - LED’s Disabled
SW-5  Detection  Mode
5 off - Dual (MW & PIR)
5 on - PIR Only
SW-6 50/60 Hz
6 off - 60Hz
6 on - 50Hz
Microwave  Sensitivity
Adjustment
uW Module Do not Touch
PIR Detector Do not Touch
Tamper Switch
3
1
2
6
4
5
The Sensitivity Adjustment
allows for MW  coverage to be
fine set to the protected area.
Preset = 50%
Max. = increases sensitivity
Min. = decreases sensitivity
OFF     ON
120%      100%     80%       60%
                      MIN.          MAX.