Cable
Use
Cable type
Number of
lines per cable
Max.
Cables
Connec-
tor type
Fiber optic
Daisy chain
connection
between two
RRHs
single mode
2
2 for
Slave /
Master
LC
Identify CPRI Configuration
Remote Radio Heads can be connected to the Base Band Unit in different ways. Make
sure which configuration is applicable.
Depending on the actual site configuration, there can be
• up to three RRHs individually connected
• one daisy chain, containing three RRHs
• two daisy chains, each containing three RRHs
• three daisy chains, each containing two RRHs
Each individual connection or daisy chain is connected to one CPRI port of the Base
Band Unit. Depending on the actual configuration the RRHs may need to be
interconnected too.
Route and connect fiber cable
NOTICE
Protect fiber cable
.
The optical fiber should be protected in solid pipe to proximate of RRH, use twine to
secure the optical fiber in the cable way (neither use tie rap), neither cut this cable on
site, the exceed length should be coil in side and protected in box. The fiber optic
connector should be protected by cap when not being used. Respect the bending radius
during the manipulation of optic cable (82.5mm).
Perform the following steps to connect the fiber optic cables to the RRH.
...................................................................................................................................................................................................
1
Locate the fiber optic cable connections for the RRH. Refer to
-- and Loosen the cable gland to allow pulling of the fiber cable.
Connect interface and DC cables
Route and connect optical fiber cables
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
6-8
Alcatel-Lucent – Proprietary
Use pursuant to applicable agreements
FDD RRH 700L
3MN-00075-0002-RJZZA
Issue 0
September 2012