Nokia of America Corporation BBTRX-06 Benutzerhandbuch

Seite von 116
Fiber distribution unit (optional)
Overview
This topic describes the optional fiber distribution unit and its connection to the RRHs.
Requirements and specifications
The fiber distribution unit is required when an RRH is pole or wall mounted and has the
following requirements and capabilities:
• Can be sited up to a distance of 14 km from the RRH
• Can connect via 3 output glands to a maximum of 12 RRHs.
Connection of 6 RRHs (3x2) via a fiber distribution unit
This example configuration shows 3 RRHs connected directly from the fiber distribution
unit and 3 RRHs connected by daisy chain
Connect interface and DC cables
Fiber distribution unit (optional)
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
6-12
Alcatel-Lucent – Proprietary
Use pursuant to applicable agreements
FDD RRH 700L
3MN-00075-0002-RJZZA
Issue 0
September 2012