2.0 
System Specifications
 
 
 
Table 1: MECHANICAL/ENVIRONMENTAL SPECIFICATIONS 
PARAMETER 
TARGET SPECIFICATIONS 
Unit Dimensions 
360.0 mm by 367.0 mm by110.0 mm=14.53  liter 
Unit Weight 
14.5 Kg 
DC Power in 
-37V to -57VV  (Nominal -48Vdc) 
Operational Temperature Range   
-40°C to +55°C 
Storage/Transportation Temperature Range 
-55ºC to +70ºC 
Enclosure Class 
IP20 
Safety and Grounding 
EN 60950-1, IEC 60950, UL 60950-1 
Storage 
ETSI EN 300 019-1-1 class 1.2, IEC 60721-3-1 
Transportation 
ETSI EN 300 019-1-2 class 2.3, IEC 60721-3-2  
Operational 
ETS 300 019-2-4 
Standards Compliance 
IEC 68 Series, ETS EN 300 019 Series 
MTBF @ 40º C 
>375,000 Hours, SR-332 
 
 
 
Table 2: SYSTEM SPECIFICATIONS 
Programmable Frequency Range 
Band12:  DL Band 729-745MHz, UL Band 699~715MHz   
Power Supply Voltage 
-48V DC 
Total Power Consumption 
475W typical
 
Receive Diversity  
2 antenna receive diversity standard 
Transmit Diversity  
2 antenna transmit diversity standard 
Receiver Noise Figure 
2.0 dB nominal, <2.2 dB at max operating temperature 
Instantaneous Bandwidth 
 
15 MHz  
# of Carriers 
3 LTE carrier with maximum 15MHz bandwidth 
Transmit Output Power 
2x 67W  (2x48.26 dBm) at antenna connector 
Output Power Accuracy 
+/- 0.5 dB 
Downlink Modulation 
LTE 
SEM/ACPR/EVM  
As defined in TS 36.104 V8.6.0 or latest 
CPRI Rate 
Support CPRI rates 1 through 5, hardware ready for rate 6 
Optical or electrical Interface 
Standard SFP modules, field loadable